Extended-Spectrum Beta-lactamase Producers: Detection for the Diagnostic Laboratory.
Аннотация
BACKGROUND AND
OBJECTIVES
Discovered in 1983, Extended spectrum beta-lactamase (ESBL) producers are still the leading cause of infections in India. Its prompt detection is crucial to the clinical management. The Clinical Laboratory Standards Institute (CLSI) recommends phenotypic screening and confirmatory tests to identify the ESBL producer making it cost and time consuming for the diagnostic laboratory. We compare here the screening and confirmatory tests offering a solution to the CLSI recommendation.
METHODS
Nosocomial isolates E. coli (71) and K. pneumoniae (25) resistant to cefotaxime and ceftazidime were included. CLSI recommended testing with cefotaxime, ceftazidime and in combination with clavulanic acid by disk diffusion and agar dilution methods were performed. E-test was performed on discrepant results. To determine the genetic relatedness of the organisms, 22 Medical and Surgical ICU isolates were genotyped by PFGE. Dendrogram was constructed using dice co-efficient, UPGMA method with diversity database software.
RESULTS AND
CONCLUSIONS
Phenotypic screening disk diffusion test versus the confirmatory agar dilution MIC tests with cefotaxime and ceftazidime correlated well with the final ESBL status (kappa 0.852 and 0.905 P < 0.001) and (kappa 0.911 and 0.822 P < 0.001). The tests show 99-100% sensitivity, 75-83.3% specificity, and positive likelihood ratios between 4.0 -5.9. E-test confirmed 6 of 12 discordant results as ESBLs. Of the 96 nosocomial isolates screened as possible ESBL producers by the Kirby-Bauer disk diffusion test, 86.5% were confirmed ESBL producers. Genotyping on the ICU isolates by PFGE revealed a genetically diverse population suggesting no transmission of phenotypically similar ESBL strains within the ICUs.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.