Leaf-Specific Classification of Multi-Leaf Collimator Positioning Errors in Volumetric Modulated Arc Therapy Using a Convolutional Neural Network.

Shin Ju Yeol, Choi Chang Heon, Kim Jung-In, Park Jong Min, Cheon Wonjoong, Park So-Yeon

СтатьяПеревод пока не подготовлен

Аннотация

Background/

Objectives

Multi-leaf collimator (MLC) positioning accuracy critically affects delivered dose fidelity in volumetric modulated arc therapy (VMAT), yet conventional gamma-based quality assurance (QA) provides only plan-level pass/fail outcomes without leaf-specific error localization. This study developed and validated a convolutional neural network (CNN) framework that classifies the magnitude and direction of individual MLC leaf positioning errors directly from fluence map data.

Methods

Three patient cohorts were analyzed: 20 prostate cancer patients for model development under an 8:1:1 train/validation/test split and 20 additional prostate and 10 head and neck (H&N) patients reserved for external validation. For inner MLC leaves 21-40, systematic offsets from -5 mm to +5 mm in 1.0 mm increments were independently applied to the two leaf banks, yielding 121 error combinations per leaf. A CNN was trained as a 121-class classifier on two-channel inputs pairing the reference and error-induced fluence map regions and was compared against three tree-based baselines using five-fold cross-validation.

Results

The CNN achieved 97.00% accuracy on the internal test set and 96.54 ± 0.43% accuracy across the five patient-level cross-validation folds. Across all test samples, 99.88% and 99.83% of predictions were within 1 mm of the true offset for Bank A and Bank B, respectively, well within the AAPM TG-142 1 mm MLC positioning tolerance. External validation yielded 96.19% accuracy on the additional prostate cohort and 93.72% on the H&N cohort, suggesting reproducibility within the same anatomical site and potential robustness across anatomically distinct treatment sites within a single-institution dataset.

Conclusions

The proposed CNN framework demonstrates the feasibility of leaf-specific identification of MLC positioning errors in both magnitude and direction from simulated fluence maps. These findings support further investigation using physically measured fluence data for future clinical translation.

Для цитирования: Shin Ju Yeol, Choi Chang Heon, Kim Jung-In, Park Jong Min, Cheon Wonjoong, Park So-Yeon. Leaf-Specific Classification of Multi-Leaf Collimator Positioning Errors in Volumetric Modulated Arc Therapy Using a Convolutional Neural Network.. Journal of clinical medicine. 2026. DOI: 10.3390/jcm15135136.