Laser versus stapler: outcomes in endoscopic repair of Zenker diverticulum.
Аннотация
OBJECTIVES/HYPOTHESIS: To analyze a single surgeon's experience with endoscopic CO(2) laser and stapler repair of Zenker diverticulum (ZD) by comparing dysphagia and regurgitation outcomes.
STUDY
DESIGN
Retrospective chart review of 148 patient charts.
METHODS
Medical records of all patients receiving endoscopic repair of ZD with either CO(2) laser (61 patients) or stapler (67 patients) were reviewed. Additional data included demographics (age and sex), size (cm), preoperative and postoperative symptoms, need for revision, and complications. Symptoms of dysphagia were graded based on a modified Functional Oral Intake Scale 1 to 4 scale (1 = normal intake; 4 = severely limited/G-tube dependent). Regurgitation was also graded on a 1 to 4 scale (1 = no regurgitation; 4 = aspiration events).
RESULTS
We noted no difference in patient age or defect size (laser, 3.26 cm; stapler, 3.53 cm; P .135). Significant differences were noted in return trips to the operating room for failed procedures (laser, 0; stapler, 7; P = .009), length of stay (laser, 3.19 days; stapler, 1.29 days; P < .001), time to oral intake (laser, 3.01 days; stapler, 1.22 days; P < .001). Significant improvement occurred in laser and staple patient symptom scales following surgery (P < .001). Laser dysphagia and regurgitation scores showed greater improvement when compared to stapler scores (P < .001).
CONCLUSIONS
Endoscopic CO(2) laser and staple methods are effective in treating ZD. The laser can have greater efficacy and result in lower recurrence rates. Both methods are analyzed and compared.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.