MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjsurg.2010.06.012

Медицинская библиотека · American journal of surgery · 2010

The number of needle passes affects the accuracy of parathyroid hormone assay with intraoperative parathyroid aspiration.

Guerrero Marlon A, Suh Insoo, Vriens Menno R, Shen Wen T, Gosnell Jessica, Kebebew Electron, Clark Orlo H, Duh Quan-Yang

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Intraoperative aspiration of a nodule and parathyroid hormone (PTH) assay has been shown to accurately confirm parathyroid tissue. However, the reported aspiration technique varies in the literature. We sought to determine if the number of passes affected the accuracy of PTH analysis.

METHODS

A prospective analysis was performed on 25 consecutive patients who underwent a parathyroidectomy for primary hyperparathyroidism. The excised parathyroid gland was aspirated using 1, 3, and 5 passes. The data were analyzed using the Wilcoxon rank, chi-square, and Fisher exact tests to calculate the 2-tailed P value.

RESULTS

Of the 26 glands aspirated, the mean PTH value varied with the number of passes, 2,073 pg/mL for 1 pass, 2,347 for 3 passes, and 2,695 for 5 passes (P = .02). Accuracy was dependent on the number of passes, with 5 passes (P = .018) having less PTH variation than 1 or 3 passes.

CONCLUSIONS

Aspiration of nodules to determine the PTH level helps confirm the presence of parathyroid tissue. The number of needle passes affects the accuracy of the PTH level, with 5 passes being the optimal number of passes to attain no false-negative results.

Для цитирования: Guerrero Marlon A, Suh Insoo, Vriens Menno R, Shen Wen T, Gosnell Jessica, Kebebew Electron, Clark Orlo H, Duh Quan-Yang. The number of needle passes affects the accuracy of parathyroid hormone assay with intraoperative parathyroid aspiration.. American journal of surgery. 2010. DOI: 10.1016/j.amjsurg.2010.06.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.