DOI 10.2967/jnumed.115.156414

Медицинская библиотека · Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2015

Performance of 11C-Pittsburgh Compound B PET Binding Potential Images in the Detection of Amyloid Deposits on Equivocal Static Images.

Hosokawa Chisa, Ishii Kazunari, Kimura Yuichi, Hyodo Tomoko, Hosono Makoto, Sakaguchi Kenta, Usami Kimio, Shimamoto Kenji, Yamazoe Yuzuru, Murakami Takamichi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

UNLABELLED: The goal of this study was to clarify whether binding potential (BP) images using (11)C-Pittsburgh compound B ((11)C-PiB) and dynamic PET can reliably detect cortical amyloid deposits for patients whose (11)C-PiB PET static images are ambiguous and whether visual ratings are affected by white matter retention.

METHODS

Static and BP images were constructed for 85 consecutive patients with cognitive impairment after (11)C-PiB dynamic PET. Cortical uptake was visually assessed as positive, negative, or equivocal for both types of images. Quantitatively, the standardized uptake value ratio (SUVR) from the static image, the nondisplaceable BP from the dynamic image for mean gray matter uptake, and the ratio of gray matter uptake to white matter retention were compared among (11)C-PiB-positive, (11)C-PiB-equivocal, and (11)C-PiB-negative groups.

RESULTS

Forty-three scans were visually assessed as (11)C-PiB-positive in both the static and the BP images. Ten scans were (11)C-PiB-equivocal in the static images. In 8 of them, the BP images were (11)C-PiB-positive, whereas the other 2 were (11)C-PiB-equivocal. Thirty-two scans were assessed as (11)C-PiB-negative in the static images. In the BP images, 4 were (11)C-PiB-positive and 2 were (11)C-PiB-equivocal. The mean gray matter uptake of (11)C-PiB in SUVR and nondisplaceable BP, respectively, showed statistically significant differences among the (11)C-PiB-positive, (11)C-PiB-equivocal, and (11)C-PiB-negative groups. The ratio of gray matter uptake to white matter retention was lower in the BP images than static images from the (11)C-PiB-negative and (11)C-PiB-equivocal groups, whereas it was higher in the (11)C-PiB-positive group.

CONCLUSION

(11)C-PiB PET BP images can clarify visual interpretation of clinical static (11)C-PiB-equivocal images by reducing the interference of nonspecific white matter retention. We conclude that (11)C-PiB-equivocal PET findings on static images reflect cortical amyloid deposits, which can be verified using BP images. Furthermore, quantitative assessments, such as SUVR and nondisplaceable BP, are of no use for correctly rating equivocal visual findings.

Для цитирования: Hosokawa Chisa, Ishii Kazunari, Kimura Yuichi, Hyodo Tomoko, Hosono Makoto, Sakaguchi Kenta, Usami Kimio, Shimamoto Kenji, Yamazoe Yuzuru, Murakami Takamichi. Performance of 11C-Pittsburgh Compound B PET Binding Potential Images in the Detection of Amyloid Deposits on Equivocal Static Images.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2015. DOI: 10.2967/jnumed.115.156414.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.