MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.31171

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2024

Coronary angiography following transcatheter aortic valve replacement: Insights from the SWEDEHEART registry.

Louca Antros, Alchay Monér, Råmunddal Truls, Rawshani Araz, Hagström Henrik, Settergren Magnus, Nilsson Konrad, Shahim Bahira, James Stefan, Koul Sasha, Myredal Anna, Redfors Björn, Ioanes Dan, Völz Sebastian, Petursson Petur, Angerås Oskar

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is the most common treatment in patients with symptomatic severe aortic stenosis (AS). As concomitant coronary artery disease is common in AS patients, access to the coronary arteries following TAVR is of increasing importance.

OBJECTIVES

This study evaluated the incidence and risk factors for unplanned coronary angiography following TAVR and, using fluoroscopic time as a surrogate, analyzed the complexity of coronary artery cannulation.

METHODS

All patients who underwent TAVR in Sweden between 2008 and 2022 were identified using the SWEDEHEART registry. The cumulative incidence of coronary angiography after TAVR was analyzed with mortality as a competing risk. Angiography and PCI complexity were analyzed using fluoroscopic time and compared across different transcatheter heart valve designs.

RESULTS

Out of 9806 patients, 566 subsequently required coronary angiography. The incidence was highest for three-vessel and/or left main disease. Younger age, the extent of prior coronary artery disease, and peripheral vascular disease were associated with an increased risk of coronary angiography. Fluoroscopy time was increased in TAVR patients compared to the control group with the longest fluoroscopy times observed in cases involving supra-annular and self-expanding valves.

CONCLUSIONS

The incidence of coronary angiography following TAVR is still low. Younger patients and patients with concomitant coronary artery disease have a higher risk. Procedural time is longer in patients with a previous THV replacement. As TAVR is emerging as the first-line treatment in patients with longer life expectancy, facilitating coronary access is an important factor when considering which THV device to implant.

Для цитирования: Louca Antros, Alchay Monér, Råmunddal Truls, Rawshani Araz, Hagström Henrik, Settergren Magnus, Nilsson Konrad, Shahim Bahira, James Stefan, Koul Sasha, Myredal Anna, Redfors Björn, Ioanes Dan, Völz Sebastian, Petursson Petur, Angerås Oskar. Coronary angiography following transcatheter aortic valve replacement: Insights from the SWEDEHEART registry.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2024. DOI: 10.1002/ccd.31171.