MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14775

Медицинская библиотека · Artificial organs · 2024

Stroke outcomes following durable left ventricular assist device implant in patients bridged with micro-axial flow pump: Insights from a large registry.

Gallone Guglielmo, Lewin Daniel, Rojas Hernandez Sebastian, Bernhardt Alexander, Billion Michael, Meyer Anna, Netuka Ivan, Kooij J-J, Pieri Marina, Szymanski Mariusz K, Moeller Christian H, Akhyari Payam, Jawad Khalil, Krasivskyi Ihor, Schmack Bastian, Färber Gloria, Medina Marta, Haneya Assad, Zimpfer Daniel, Nersesian Gaik, Lanmueller Pia, Spitaleri Antonio, Oezkur Mehmet, Djordjevic Ilija, Saeed Diyar, Boffini Massimo, Stein Julia, Gustafsson F, Scandroglio Anna Mara, De Ferrari Gaetano Maria, Meyns Bart, Hofmann Steffen, Belohlavek Jan, Gummert Jan, Rinaldi Mauro, Potapov Evgenij V, Loforte Antonio

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled.

METHODS

Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied.

RESULTS

Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality.

CONCLUSIONS

Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

Для цитирования: Gallone Guglielmo, Lewin Daniel, Rojas Hernandez Sebastian, Bernhardt Alexander, Billion Michael, Meyer Anna, Netuka Ivan, Kooij J-J, Pieri Marina, Szymanski Mariusz K, Moeller Christian H, Akhyari Payam, Jawad Khalil, Krasivskyi Ihor, Schmack Bastian, Färber Gloria, Medina Marta, Haneya Assad, Zimpfer Daniel, Nersesian Gaik, Lanmueller Pia, Spitaleri Antonio, Oezkur Mehmet, Djordjevic Ilija, Saeed Diyar, Boffini Massimo, Stein Julia, Gustafsson F, Scandroglio Anna Mara, De Ferrari Gaetano Maria, Meyns Bart, Hofmann Steffen, Belohlavek Jan, Gummert Jan, Rinaldi Mauro, Potapov Evgenij V, Loforte Antonio. Stroke outcomes following durable left ventricular assist device implant in patients bridged with micro-axial flow pump: Insights from a large registry.. Artificial organs. 2024. DOI: 10.1111/aor.14775.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.