MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5694/mja2.52302

Медицинская библиотека · The Medical journal of Australia · 2024

Factors associated with cardiac implantable electronic device-related infections, New South Wales, 2016-21: a retrospective cohort study.

Shawon Md Shajedur Rahman, Sotade Oluwadamisola T, Li Joan, Hill Michelle D, Strachan Liesl, Challis Gabrielle, King Kate, Ooi Sze-Yuan, Jorm Louisa

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To quantify the rate of cardiac implantable electronic device (CIED)-related infections and to identify risk factors for such infections.

DESIGN

Retrospective cohort study; analysis of linked hospital admissions and mortality data.

SETTING,

PARTICIPANTS

All adults who underwent CIED procedures in New South Wales between 1 January 2016 and 30 June 2021 (public hospitals) or 30 June 2020 (private hospitals).

MAIN OUTCOME MEASURES: Proportions of patients hospitalised with CIED-related infections (identified by hospital record diagnosis codes); risk of CIED-related infection by patient, device, and procedural factors.

RESULTS

Of 37 675 CIED procedures (23 194 men, 63.5%), 500 were followed by CIED-related infections (median follow-up, 24.9 months; interquartile range, 11.2-40.8 months), including 397 people (1.1%) within twelve months of their procedures, and 186 of 10 540 people (2.5%) at high risk of such infections (replacement or upgrade procedures; new cardiac resynchronisation therapy with defibrillator, CRT-D). The overall infection rate was 0.50 (95% confidence interval [CI], 0.45-0.54) per 1000 person-months; it was highest during the first month after the procedure (5.60 [95% CI, 4.89-6.42] per 1000 person-months). The risk of CIED-related infection was greater for people under 65 years of age than for those aged 65-74 years (adjusted hazard ratio [aHR], 1.71; 95% CI, 1.32-2.23), for people with CRT-D devices than for those with permanent pacemakers (aHR, 1.46; 95% CI, 1.02-2.08), for people who had previously undergone CIED procedures (two or more v none: aHR, 1.51; 95% CI, 1.02-2.25) or had CIED-related infections (aHR, 11.4; 95% CI, 8.34-15.7), or had undergone concomitant cardiac surgery (aHR, 1.62; 95% CI, 1.10-2.39), and for people with atrial fibrillation (aHR, 1.33; 95% CI, 1.11-1.60), chronic kidney disease (aHR, 1.54; 95% CI, 1.27-1.87), chronic obstructive pulmonary disease (aHR, 1.37; 95% CI, 1.10-1.69), or cardiomyopathy (aHR 1.60; 95% CI, 1.25-2.05).

CONCLUSIONS

Knowledge of risk factors for CIED-related infections can help clinicians discuss them with their patients, identify people at particular risk, and inform decisions about device type, upgrades and replacements, and prophylactic interventions.

Для цитирования: Shawon Md Shajedur Rahman, Sotade Oluwadamisola T, Li Joan, Hill Michelle D, Strachan Liesl, Challis Gabrielle, King Kate, Ooi Sze-Yuan, Jorm Louisa. Factors associated with cardiac implantable electronic device-related infections, New South Wales, 2016-21: a retrospective cohort study.. The Medical journal of Australia. 2024. DOI: 10.5694/mja2.52302.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.