MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09553002.2026.2705994

Медицинская библиотека · International journal of radiation biology · 2026

Dosimetric impact of spatial separation in combined SBRT and mediastinal radiotherapy for peripheral small cell lung cancer.

Siah Ningjing, Liu Hongyuan, Hu Ting, Wang Geng, Wu Gang, Yu Chuanchuan, Zhang Sheng, Dong Xiaorong, Zhou Rui

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the dosimetric feasibility of combining stereotactic body radiotherapy (SBRT) for peripheral tumors with conventionally fractionated mediastinal lymph node (MLN) radiotherapy in small cell lung cancer (SCLC), with a focus on tumor-nodal spatial separation and geometry-dependent dose redistribution.

MATERIALS AND

METHODS

A retrospective virtual planning study was conducted in 21 patients with peripheral SCLC. Three treatment strategies were generated: (1) SBRT 40 Gy in 5 fractions plus MLN radiotherapy 60 Gy in 30 fractions, (2) SBRT 50 Gy in 5 fractions plus MLN radiotherapy, and (3) conventional thoracic radiotherapy (60 Gy in 30 fractions). Target coverage and dose-volume parameters for organs at risk (OARs) were compared. Biological dose normalization using equivalent dose in 2 Gy fractions (EQD2), based on the linear-quadratic model, and prescription-matched sensitivity analyses were performed.

RESULTS

All strategies achieved adequate target coverage. SBRT-based approaches significantly reduced low-dose lung exposure compared with conventional radiotherapy, particularly in the 40 Gy regimen (lung V5 - 7.34%, V10 - 3.34%, V20 - 2.20%; all p ≤ 0.003), along with a reduction in mean lung dose (-125.74 cGy, p < .001). In exploratory EQD2-normalized analysis, the reduction in mean lung dose remained statistically significant (-0.95 Gy EQD2, p < .001). In prescription-matched analyses, lung V5 remained significantly lower, indicating that differences were not solely attributable to prescription dose. Patients with tumor-nodal spatial separation ≥2 cm exhibited lower doses to multiple OARs, supporting a geometry-dependent reduction in normal tissue exposure.

CONCLUSIONS

Combining SBRT with MLN radiotherapy is dosimetrically feasible in selected patients with SCLC, with feasibility strongly influenced by tumor-nodal spatial separation. Reduced low-dose lung exposure appears to be associated with geometry-dependent dose redistribution. These findings provide a rationale for further investigation of geometry-informed treatment strategies in prospective clinical studies.

Для цитирования: Siah Ningjing, Liu Hongyuan, Hu Ting, Wang Geng, Wu Gang, Yu Chuanchuan, Zhang Sheng, Dong Xiaorong, Zhou Rui. Dosimetric impact of spatial separation in combined SBRT and mediastinal radiotherapy for peripheral small cell lung cancer.. International journal of radiation biology. 2026. DOI: 10.1080/09553002.2026.2705994.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.