MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2016.05.003

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2016

The variability of corneal and anterior segment parameters in keratoconus.

Mas-Aixala Enric, Gispets Joan, Lupón Núria, Cardona Genís

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyse, describe and test diverse corneal and anterior segment parameters in normal and keratoconic eyes to better understand the geometry of the keratoconic cornea.

METHOD: 44 eyes from 44 keratoconic patients and 44 eyes from 44 healthy patients were included in the study. The Pentacam System was used for the analysis of the anterior segment parameters. New ad-hoc parameters were defined by measuring the distances on the Scheimpflug image at the horizontal diameter, with chamber depth now comprising of two distinctive distances: corneal sagittal depth and the distance from the endpoint of this segment to the anterior surface of the lens (DL).

RESULTS

Statistically significant differences (p<0.05) between normal and keratoconic eyes were found in all of the analysed corneal parameters. Anterior chamber depth presented statistical differences between normal and keratoconic eyes (3.06±0.43mm versus 3.34±0.45mm, respectively; p=0.004). This difference was found to originate in an increase of the DL distance (0.40±0.33mm in normal eyes against 0.61±0.45mm in keratoconic eyes; p=0.014), rather than in the changes in corneal sagittal depth.

CONCLUSION

These findings indicate that keratoconus results in central and peripheral corneal manifestations, as well as changes in the shape of the scleral limbus. The DL parameter was useful in describing the forward elongation and advance of the scleral tissue in keratoconic eyes. This finding may help in the monitoring of disease progression and contact lens design and fitting.

Для цитирования: Mas-Aixala Enric, Gispets Joan, Lupón Núria, Cardona Genís. The variability of corneal and anterior segment parameters in keratoconus.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2016. DOI: 10.1016/j.clae.2016.05.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.