DOI 10.1007/bf01745241

Медицинская библиотека · Heart and vessels · 1994

Characteristics of left-ventricular isovolumic pressure waves in isolated dog hearts.

Regen D M, Denton P K, Howe W C, Taylor L K, Hansen D E

СтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

The peak pressure which a chamber would develop in isovolumic contraction at end-diastolic distention (peak source pressure) is an expression of contractile vigor and a determinant of systolic performance. One can predict source pressure of an ejecting beat by fitting its isovolumic phases with a model isovolumic-wave function. Characteristics of the left-ventricular isovolumic pressure wave (amplitude, duration, shape) were studied in isolated, perfused, artificially loaded dog hearts, where strictly isovolumic conditions could be obtained over a wide range of cavity volumes at constant heart rate and approximately constant contractile state. The characterization involved two steps: (1) beginning and ending points were identified by a transition-locating algorithm, and (2) Fourier analysis was performed on points in between. The amplitude of the isovolumic pressure wave increased with cavity volume as expected, the duration of contraction increased with cavity volume, and the shape of the wave (normalized Fourier coefficients) depended slightly on the cavity volume. Duration of contraction declined slightly with increasing heart rate, but the shape of the isovolumic pressure wave was independent of heart rate. The mean shape was similar to that found in dog hearts subjected to one-beat aortic-root clamping in vivo-the wave being less sharply peaked than a cosine wave and tilted to the left because relaxation was slower than contraction. When ejecting beat duration declined linearly with increasing ejection fraction. This relation could be used to predict the duration of the isovolumic beat corresponding to the duration of an ejecting beat. Source pressure could then be predicted by fitting a model isovolumic wave of predicted duration to the isovolumic contraction phase of the ejecting beat. In 270 comparisons, the ratio of predicted peak source pressure to observed peak source pressure was 1.04 +/- 0.10 (SD). This method provides a reasonably accurate prediction of an important determinant of systolic performance.

Для цитирования: Regen D M, Denton P K, Howe W C, Taylor L K, Hansen D E. Characteristics of left-ventricular isovolumic pressure waves in isolated dog hearts.. Heart and vessels. 1994. DOI: 10.1007/bf01745241.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.