Intrastromal corneal ring segments delay corneal grafting in patients with keratoconus.

Beniz Luiz Arthur F, Queiroz Gustavo H, Queiroz Carlos F, Lopes Wanessa L, Moraes Leiser F, Beniz José

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the impact of intrastromal corneal ring segments (ICRS) as a surgical alternative to corneal grafting in patients with keratoconus who were scheduled for a corneal transplant.

METHODS

This single-surgeon, single-center, retrospective, observational case series study included 19 eyes of 18 patients (mean age, 23.36 ± 6.22 years) with a confirmed diagnosis of keratoconus. These patients were enrolled from the State of Goiás, Brazil corneal graft waiting list. Following extensive pre-operative testing, including the measurement of best-corrected visual acuity (BCVA), applanation tonometry, biomicroscopy, funduscopy, pachymetry, and corneal topography, patients were implanted with Keraring® ICRS. Patients underwent clinical examination at postoperative days 1, 7, 30, 90, and 180 and were examined again 2 years following surgery.

RESULTS

At the 2-year cut-off following ICRS implantation (mean follow-up, 28.72 ± 4.71 months), there was a statistically significant improvement in BCVA (logMAR) from 0.59 ± 0.35 preoperatively to 0.35 ± 0.45 postoperatively ( p <0.01). Three of 19 eyes (15.8%) still required keratoplasty. In the remaining patients (84.2%), BCVA was managed with spectacles (52.6%) or contact lenses (31.6%). One patient developed infectious keratitis, requiring removal of ICR at the first postoperative visit.

CONCLUSION

ICRS implantation may be a surgical alternative to keratoplasty in patients with keratoconus. This procedure may delay or even eliminate the need for keratoplasty in such patients.

Для цитирования: Beniz Luiz Arthur F, Queiroz Gustavo H, Queiroz Carlos F, Lopes Wanessa L, Moraes Leiser F, Beniz José. Intrastromal corneal ring segments delay corneal grafting in patients with keratoconus.. Arquivos brasileiros de oftalmologia. 2016. DOI: 10.5935/0004-2749.20160009.