DOI 10.1016/j.jcrs.2015.04.033

Медицинская библиотека · Journal of cataract and refractive surgery · 2015

Corneal stromal demarcation line after accelerated crosslinking using continuous and pulsed light.

Moramarco Antonio, Iovieno Alfonso, Sartori Antonio, Fontana Luigi

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate and compare the depth of corneal stromal demarcation line after accelerated collagen crosslinking (CXL) using continuous and pulsed light ultraviolet-A (UVA) exposure.

SETTING

Department of Ophthalmology, Arcispedale Santa Maria Nuova, Reggio Emilia, Italy.

DESIGN

Retrospective case series.

METHODS

Patients with progressive keratoconus were assigned to 1 of 2 treatment protocols using the same irradiation device for accelerated CXL. Patients assigned to Group A received accelerated CXL using continuous UVA light exposure at 30 mW/cm(2) for 4 minutes. Patients assigned to Group B received accelerated CXL using pulsed UVA light with 8 minutes (1 second on/1 second off) of UVA exposure at 30 mW/cm(2) and energy dose of 7.2 J/cm(2). One month after surgery, corneal stromal demarcation line depth was measured by 2 independent observers using anterior segment optical coherence tomography (AS-OCT).

RESULTS

A total of 60 patients were assessed. Corneal stromal demarcation line was easily identified on AS-OCT scans in all eyes by both observers. The mean depth of stromal demarcation line was 149.32 ± 36.03 μm in Group A and 213 ± 47.38 μm in Group B. The difference in stromal demarcation line depth between groups was statistically significant (P < .001).

CONCLUSIONS

Using accelerated CXL, the corneal stromal demarcation line was significantly deeper using pulsed rather than continuous light exposure.

FINANCIAL DISCLOSURE: No author has financial or proprietary interest in any material or method mentioned.

Для цитирования: Moramarco Antonio, Iovieno Alfonso, Sartori Antonio, Fontana Luigi. Corneal stromal demarcation line after accelerated crosslinking using continuous and pulsed light.. Journal of cataract and refractive surgery. 2015. DOI: 10.1016/j.jcrs.2015.04.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.