Efficacy of axial and tangential corneal topography maps in detecting subclinical keratoconus.

Tummanapalli Shyam Sunder, Potluri Haresh, Vaddavalli Pravin Krishna, Sangwan Virender S

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate and compare the efficacy of axial and tangential corneal topography maps obtained using the Orbscan IIz scanning-slit device to distinguish differences in eyes with subclinical keratoconus from normal eyes.

SETTING

LV Prasad Eye Institute, Hyderabad, India.

DESIGN

Retrospective cross-sectional study.

METHODS

Axial and tangential maps of the anterior and posterior corneal surfaces were obtained in eyes of patients with subclinical keratoconus (normal fellow eye of an eye with clinically diagnosed keratoconus). The following measurements were obtained from each map and compared between the 2 groups: location of the corneal apex in millimeters relative to the corneal vertex, dioptric power at the corneal apex and corneal vertex, corneal irregularity indices at 3.0 mm and 5.0 mm, anterior-posterior apex ratio, and inferior-superior dioptric asymmetry value.

RESULTS

Maps were obtained in 71 eyes (71 patients) with subclinical keratoconus and 76 normal eyes (76 patients). The tangential posterior apex curvature was significantly steeper than the axial posterior apex curvature in both groups (P < .001). The anterior-posterior apex ratio on the tangential map demonstrated the highest area under the receiver operating characteristic (ROC) curve of 0.992 (cutoff ≥-6.97, sensitivity 98.6%, specificity 98.7%) followed by the posterior irregularity index in the 5.0 mm zone with an area under the ROC curve of 0.938 (cutoff ≥0.4, sensitivity 98.6%, specificity 84.2%) in differentiating subclinical keratoconus eyes from normal eyes.

CONCLUSIONS

The anterior-posterior apex ratio on the tangential map and 5.0 mm irregularity index of the posterior corneal surface were highly sensitive and specific for early detection of subclinical keratoconus. Tangential corneal topography maps should be considered in preoperative subclinical keratoconus screening.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Tummanapalli Shyam Sunder, Potluri Haresh, Vaddavalli Pravin Krishna, Sangwan Virender S. Efficacy of axial and tangential corneal topography maps in detecting subclinical keratoconus.. Journal of cataract and refractive surgery. 2015. DOI: 10.1016/j.jcrs.2015.10.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.