Should a VVIR pacemaker increase the heart rate with standing?

Leitch J W, Arnold J M, Klein G J, Yee R, Riff K

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To assess the usefulness of incorporating a posture sensor into a ventricular inhibited rate modulated pacemaker, the hemodynamic effects of increasing the ventricular pacing rate with standing were studied in 15 pacemaker dependent patients aged 55 +/- 3.5 years. In a randomized cross-over design, the pacing rate remained at 70 or was increased to 100 beats/min immediately prior to standing. Blood pressure was monitored continuously and forearm blood flow was measured by venous occlusion plethysmography. There was no difference in supine blood pressure (117 +/- 4/63 +/- 3 compared to 118 +/- 5/64 +/- 4 mmHg) or forearm blood flow (2.88 +/- 0.36 vs 2.94 +/- 0.32 mL/100 mL/min) before the 70 or 100 pacing rate intervention. With standing, blood pressure fell to an equivalent degree at the two pacing rates (fall in mean blood pressure at 70 beats/min 6 +/- 4 and at 100 beats/min 8 +/- 2 mmHg, P = 0.7). After 1 minute of standing differences in blood pressure were similar, but after 2.5 minutes of standing the increase in mean blood pressure was less at 70 than at 100 beats/min (increase from control 28 +/- 2 compared to 36 +/- 3 mmHg, P = 0.002). Forearm blood flow decreased after standing for 1 and 2.5 minutes but there was no difference between the 70 and 100 pacing rates (fall in forearm blood flow at 2.5 minutes 0.50 +/- 0.24 and 0.59 +/- 0.25 mL/100 mL/cm2).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Leitch J W, Arnold J M, Klein G J, Yee R, Riff K. Should a VVIR pacemaker increase the heart rate with standing?. Pacing and clinical electrophysiology : PACE. 1992. DOI: 10.1111/j.1540-8159.1992.tb06498.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.