Intraocular pressure evaluation in healthy eyes and diseased ones using contact and non contact devices.

Lanza Michele, Iaccarino Stefania, Mele Luigi, Carnevale Ugo Antonello Gironi, Irregolare Carlo, Lanza Alessandro, Femiano Felice, Bifani Mario

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze and compare intraocular pressure (IOP) values measured in healthy subjects (HS), keratoconus (KC) patients and patients that underwent myopic photorefractive keratectomy (REF), using Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), ocular response analyzer (ORA) and Corvis ST (CST).

METHODS

The study included 76 eyes of 76HS, 15 eyes of 15 KC patients and 18 eyes of 18 subjects that underwent REF. Each participant underwent a complete ophthalmic evaluation, IOP measurement with GAT, DCT, ORA and CST.

RESULTS

HS showed a mean GAT value of 15.62±2.33 mm Hg, a mean DCT value of 17.44±2.51 mm Hg, a mean ORA value of 15.99±3.58 mm Hg and a mean CST value of 17.24±3.44 mm Hg. KC showed a mean GAT value of 15.07±1.83 mm Hg, a mean DCT value of 17.01±1.96 mm Hg, a mean ORA value of 13.58±2.99 mm Hg and a mean CST value of 14.37±1.89 mm Hg. REF showed a mean GAT value of 14.06±1.51 mm Hg, a mean DCT value of 15.12±2.34 mm Hg, a mean ORA value of 16.85±2.4 mm Hg and a mean CST value of 15.57±1.77 mm Hg.

CONCLUSION

Our data suggest that ORA and GAT could be used interchangeably in HS; GAT, ORA and CST could be used interchangeably in KC patients and that GAT provides lower IOP values compared to the other devices in eyes previously submitted to myopic PRK.

Для цитирования: Lanza Michele, Iaccarino Stefania, Mele Luigi, Carnevale Ugo Antonello Gironi, Irregolare Carlo, Lanza Alessandro, Femiano Felice, Bifani Mario. Intraocular pressure evaluation in healthy eyes and diseased ones using contact and non contact devices.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2015. DOI: 10.1016/j.clae.2015.10.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.