The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera® scleral contact lens fitting process.

Weber Sarah La Porta, Ambrósio Renato, Lipener César, Coral-Ghanem Cleusa, Hofling-Lima Ana Luisa

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To test for associations between Pentacam(®) derived topography variables and to evaluate the predictive power of those variables in relation to scleral contact lens (SCL) fit.

SETTING

Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo-SP, Brazil.

DESIGN

Prospective observational non-randomised, non-comparative study.

METHODS

Forty-seven patients (63 eyes) were indicated for the use of Esclera(®) SCL. All patients underwent Scheimpflug imaging before the initial SCL evaluation. The following parameters were measured by Pentacam: corneal elevations, thickness, density, and anterior chamber depth (ACD). Correlations between the SCL parameters and the Pentacam measurements were analysed with Pearson's correlation coefficients. A simple linear regression model was created for each lens parameter using the most-correlated Pentacam variable.

RESULTS

In the total group, the results show correlations between the SCL parameters and the corneal astigmatism, ACD and pentacam-measured corneal height (Hm), with p<0.001 each. In addition, an inverse correlation between the lens sagittal depth (LSD) and the anterior radii minimum was shown (p<0.001). In the keratoconus group, the results show correlations between the SCL parameters and ACD and Hm (p<0.001, each). An inverse correlation between the LSD and the total thickness corneal density average was also observed (p=0.003).

CONCLUSION

There was a positive correlation between the LSD and ACD, even as LD and ACD in the keratoconus group. Thus, these results suggest that certain Pentacam measurements can be good predictors of the most appropriate Esclera lens to be fitted in keratoconus patients.

Для цитирования: Weber Sarah La Porta, Ambrósio Renato, Lipener César, Coral-Ghanem Cleusa, Hofling-Lima Ana Luisa. The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera® scleral contact lens fitting process.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2015. DOI: 10.1016/j.clae.2015.09.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.