Quantitative analysis of iris parameters in keratoconus patients using optical coherence tomography.

Bonfadini Gustavo, Arora Karun, Vianna Lucas M, Campos Mauro, Friedman David, Muñoz Beatriz, Jun Albert S

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the relationship between quantitative iris parameters and the presence of keratoconus.

METHODS

Cross-sectional observational study that included 15 affected eyes of 15 patients with keratoconus and 26 eyes of 26 normal age- and sex-matched controls. Iris parameters (area, thickness, and pupil diameter) of affected and unaffected eyes were measured under standardized light and dark conditions using anterior segment optical coherence tomography (AS-OCT). To identify optimal iris thickness cutoff points to maximize the sensitivity and specificity when discriminating keratoconus eyes from normal eyes, the analysis included the use of receiver operating characteristic (ROC) curves.

RESULTS

Iris thickness and area were lower in keratoconus eyes than in normal eyes. The mean thickness at the pupillary margin under both light and dark conditions was found to be the best parameter for discriminating normal patients from keratoconus patients. Diagnostic performance was assessed by the area under the ROC curve (AROC), which had a value of 0.8256 with 80.0% sensitivity and 84.6% specificity, using a cutoff of 0.4125 mm. The sensitivity increased to 86.7% when a cutoff of 0.4700 mm was used.

CONCLUSIONS

In our sample, iris thickness was lower in keratoconus eyes than in normal eyes. These results suggest that tomographic parameters may provide novel adjunct approaches for keratoconus screening.

Для цитирования: Bonfadini Gustavo, Arora Karun, Vianna Lucas M, Campos Mauro, Friedman David, Muñoz Beatriz, Jun Albert S. Quantitative analysis of iris parameters in keratoconus patients using optical coherence tomography.. Arquivos brasileiros de oftalmologia. 2015. DOI: 10.5935/0004-2749.20150080.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.