MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000000598

Медицинская библиотека · Cornea · 2015

Screening for Keratoconus With New Dynamic Biomechanical In Vivo Scheimpflug Analyses.

Steinberg Johannes, Katz Toam, Lücke Kristina, Frings Andreas, Druchkiv Vasyl, Linke Stephan J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To improve keratoconus (KC) screening with new in vivo biomechanical Scheimpflug analyses.

METHODS

After adjusting for intraocular pressure and corneal thickness, predefined static and new dynamic Scheimpflug curve analyses [Pentacam HR and Corvis ST (CST); Oculus] of 87 normal eyes, 27 subclinical KC eyes, 42 suspected KC, and 65 manifest KC eyes were reviewed retrospectively. A t test (for a normal distribution), Wilcoxon matched-pairs test (if not normally distributed), and receiver operating characteristics were used to test for statistically significant differences between these groups. In addition, new dynamic curve analyses were performed to analyze corneal dynamics throughout the entire response to the CST air puff impulse.

RESULTS

Comparing normal and KC-suspect eyes, the parameters A1 length, A2 length, radius of the inward-bended cornea, and deflection length at the highest concavity revealed statistically significant differences. In addition, the newly calculated "applanation length level" and "deflection length level" demonstrated consistently increasing differences with increasing statistical significance between normal eyes and those with advancing KC stages. However, when comparing normal and subclinical KC eyes, none of the analyzed parameters demonstrated statistically significant differences.

CONCLUSIONS

In vivo biomechanical analyses (CST) at their current state only marginally improve KC screening protocols. Newly generated parameters such as the applanation length level and deflection length level might further improve early KC screening.

Для цитирования: Steinberg Johannes, Katz Toam, Lücke Kristina, Frings Andreas, Druchkiv Vasyl, Linke Stephan J. Screening for Keratoconus With New Dynamic Biomechanical In Vivo Scheimpflug Analyses.. Cornea. 2015. DOI: 10.1097/ico.0000000000000598.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.