Screening for Subclinical Keratoconus Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography.

Steinberg Johannes, Casagrande Maria K, Frings Andreas, Katz Toam, Druchkiv Vasyl, Richard Gisbert, Linke Stephan J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To discriminate between subclinical fellow eyes of patients with keratoconus (scKCE) and normal eyes (NE) using swept-source Fourier-domain anterior segment optical coherence tomography (SS-OCT).

SETTING

University Medical Center Hamburg-Eppendorf, Germany.

DESIGN

Retrospective cross-sectional study.

METHODS

NE (both eyes with a KISA% Index <60; N = 213) and scKCE (KISA% Index <60, but an index of >100 in the fellow eye; N = 61) eyes were grouped according to the KISA% Index. Topography and tomography data were obtained by SS-OCT (Casia SS1000) and reviewed retrospectively. Receiver operating characteristics were performed for Casia SS1000 integrated automated parameters and newly computed indices. Additionally, discriminant functions were calculated for the automated single parameters, the computed indices, and the combination of both.

RESULTS

An accuracy ≥0.7 was reached for 28 (8 automated and 20 newly computed parameters) of 785 parameters. Fourier analysis posterior higher-order irregular astigmatism revealed the highest accuracy with 0.81. By combining automated parameters with the newly computed indices in 1 discriminant function, an area under the curve of 0.92 with a corresponding accuracy of 0.85 was achieved.

CONCLUSIONS

SS-OCT is able to discriminate between NE and scKCE with high accuracy. Automated single parameters and newly computed indices were combined to further improve this accuracy.

Для цитирования: Steinberg Johannes, Casagrande Maria K, Frings Andreas, Katz Toam, Druchkiv Vasyl, Richard Gisbert, Linke Stephan J. Screening for Subclinical Keratoconus Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography.. Cornea. 2015. DOI: 10.1097/ico.0000000000000568.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.