Assessment of the correlation of the tear breakup time with quality of vision and dry eye symptoms after SMILE surgery.
Аннотация
PURPOSE: It is well reported that dry eye symptoms can increase after many refractive surgery procedures. This study aims to provide a clinical understanding of the correlation of fluorescein tear film breakup time (FTBUT) with quality of vision (QoV) and dry eye symptoms following small incision lenticule extraction surgery (SMILE).
METHODS
Patients electing to have SMILE surgery were subdivided into 2 groups: Group 1 included short preoperative FTBUTs of 3 to 6 seconds (s); Group 2 included long FTBUTs of ≥ 8 s. Uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction, FTBUT, QoV and Ocular Surface Disease Index (OSDI) questionnaires were recorded 1 and 6 months postoperatively.
RESULTS
Thirty-nine subjects were included in each group. There was no significant difference in visual outcomes between the 2 groups at both the 1- and 6-month postoperative assessments. FTBUT remained significantly lower in group 1. Oxford staining was initially higher for group 1 at 1 month (P = 0.007), but there was no significant difference at 6 months (P = 0.180). There was no significant difference in QoV or OSDI scores between the 2 groups at both postoperative visits.
CONCLUSIONS
Low preoperative FTBUT (3-6 s) does not appear to negatively affect postoperative visual outcomes or results in a greater likelihood of dry eye symptoms and poor ocular surface compared to eyes with a longer preoperative FTBUT. These results suggest that a low preoperative FTBUT does not necessarily increase the likelihood of poor visual acuity, dry eyes symptoms, or poor ocular surface outcomes following SMILE surgery.