Аннотация

PURPOSE OF THE REPORT: When thyroid scintigraphy (TS) is performed after contrast-enhanced CT (CE-CT), tracer uptake of 99mTcO4 in the thyroid gland can be inhibited by free iodide. Currently, it is recommended to postpone TS until 4 to 8 weeks after CE-CT, but few data exist to support this recommendation. The purpose was to investigate the effect of CE-CT and other variables for the diagnostic quality of TS.

PATIENTS AND

METHODS

This retrospective study included 196 patients subjected to TS less than 3 months after a CE-CT (median, 66 days). Patients with elevated thyroid-stimulating hormone (>4.5 mIU/L) or suspected thyroiditis were excluded. Logistic regression was used to calculate the probability of a TS of diagnostic quality with the variables days since CE-CT, age, thyroid-stimulating hormone, and kidney function (eGFR).

RESULTS

Days since CT and age were highly significant (P < 0.001) predictors for diagnostic TS. The probability of diagnostic quality TS after CE-CT increased with time and reached approximately 70% to 80% 6 to 8 weeks after CE-CT. Analysis of age-specific populations showed age to be a strong independent factor.

CONCLUSIONS

Our findings are in consensus with the currently recommended interval of 6 to 8 weeks between CE-CT and TS. However, our results indicate that patient age should be taken into account, and we suggest the following delay from CE-CT to TS: 4 weeks for patients aged younger than 50 years, 6 weeks for patients aged 50 to 60 years, and 8 weeks for patients aged older than 60 years.

Для цитирования: Andersen Trine Borup, Aleksyniene Ramune, Gormsen Lars Christian, Jødal Lars, Petersen Lars J. Effect of recent contrast-enhanced CT and patient age on image quality of thyroid scintigraphy.. Clinical nuclear medicine. 2015. DOI: 10.1097/rlu.0000000000000726.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.