DOI 10.1097/tp.0b013e3181949d4e
Multicenter evaluation of a novel endothelial cell crossmatch test in kidney transplantation.
Аннотация
BACKGROUND
Despite their clinical importance, clinical routine tests to detect anti-endothelial cell antibodies (AECA) in organ transplantation have not been readily available. This multicenter prospective kidney transplantation trial evaluates the efficacy of a novel endothelial cell crossmatch (ECXM) test to detect donor-reactive AECA associated with kidney allograft rejection.
METHODS
Pretransplant serum samples from 147 patients were tested for AECA by a novel flow cytometric crossmatch technique (XM-ONE) using peripheral blood endothelial progenitor cells as targets. Patient enrolment was based on acceptance for transplantation determined by donor lymphocyte crossmatch results.
RESULTS
Donor-reactive AECA were found in 35 of 147 (24%) patients. A significantly higher proportion of patients with a positive ECXM had rejections (16 of 35, 46%) during the follow-up of at least 3 months compared with those without AECA (13 of 112, 12%; P<0.00005). Both IgG and IgM AECAs were associated with graft rejections. Mean serum creatinine levels were significantly higher in patients with a positive ECXM test at 3 and 6 months posttransplant.
CONCLUSIONS
XM-ONE is quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte crossmatches.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.