Safety of Retinopathy of Prematurity Examination and Imaging in Premature Infants.

Wade Kelly C, Pistilli Maxwell, Baumritter Agnieshka, Karp Karen, Gong Alice, Kemper Alex R, Ying Gui-Shuang, Quinn Graham, e-Retinopathy of Prematurity Study Cooperative Group

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To describe adverse events (AEs) and noteworthy clinical or ocular findings associated with retinopathy of prematurity (ROP) evaluation procedures.

STUDY

DESIGN

Descriptive analysis of predefined AEs and noteworthy findings reported in a prospective observational cohort study of infants <1251 g birth weight who had ROP study visits consisting of both binocular indirect ophthalmoscopy (BIO) and digital retinal imaging. We compared infant characteristics during ROP visits with and without AEs. We compared respiratory support, nutrition, and number of apnea, bradycardia, or hypoxia events 12 hours before and after ROP visits.

RESULTS

A total of 1257 infants, mean birth weight 802 g, had 4263 BIO and 4048 imaging sessions (total 8311 procedures). No serious AEs were related to ROP visits. Sixty-five AEs were reported among 61 infants for an AE rate of 4.9% infants (61/1257) or 0.8% total procedures (65/8311 BIO + imaging). Most AEs were due to apnea, bradycardia, and/or hypoxia (68%), tachycardia (16%), or emesis (8%). At ROP visit, infants with AEs, compared with those without, were more likely to be on mechanical ventilation (26% vs 12%, P = .04) even after adjustment for weight and postmenstrual age. Noteworthy clinical findings were reported during 8% BIO and 15% imaging examinations. Respiratory and nutrition support were not significantly different before and after ROP evaluations.

CONCLUSIONS

Retinal imaging by nonphysicians combined with BIO was safe. Noteworthy clinical findings occurred during both procedures. Ventilator support was a risk factor for AEs. Monitoring rates of AEs and noteworthy findings are important to the safe implementation of ROP imaging protocols.

TRIAL REGISTRATION: Clinicaltrials.gov: NCT01264276.

Для цитирования: Wade Kelly C, Pistilli Maxwell, Baumritter Agnieshka, Karp Karen, Gong Alice, Kemper Alex R, Ying Gui-Shuang, Quinn Graham, e-Retinopathy of Prematurity Study Cooperative Group. Safety of Retinopathy of Prematurity Examination and Imaging in Premature Infants.. The Journal of pediatrics. 2015. DOI: 10.1016/j.jpeds.2015.07.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.