MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1051-0443(97)70568-2

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 1997

Acute rupture of the descending thoracic aorta: repair with use of endovascular stent-grafts.

Semba C P, Kato N, Kee S T, Lee G K, Mitchell R S, Miller D C, Dake M D

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the use of endovascular stent-grafts to treat acute ruptures of the descending thoracic aorta as an alternative to surgery in high-risk patients.

MATERIALS AND

METHODS

From July 1992 to August 1996, 95 patients underwent stent-grafting of the descending thoracic aorta for a variety of lesions. Of these, 11 patients with acute (< or = 7 days) rupture from aneurysms (n = 8) or trauma (n = 3) underwent repair with use of endovascular stent-grafts. Rupture was confirmed with preoperative imaging studies and occurred in the mediastinum (n = 9), the pleural space (n = 1), or the lung (n = 1). All patients were considered high surgical risk due to generalized cardiopulmonary disease and/or previous thoracotomies. Stent-grafts were constructed from Z stents covered with polyester fabric and delivered through a catheter under fluoroscopic control from a remote access site.

RESULTS

Stent-graft deployment was successful in all patients. There were no complications of perigraft leak, stent migration, paraplegia, or intraoperative death. Two patients died in the follow-up period: one of ventricular perforation during unrelated thoracic surgery for tumor resection (day 1) and one of cardiac arrest (day 28). All others are alive (mean follow-up, 15.1 months).

CONCLUSION

For acute rupture of the thoracic aorta, endovascular stent-graft repair is technically feasible and may be a therapeutic alternative to a surgical interposition graft in patients considered high risk for conventional thoracotomy. Long-term studies are necessary to determine the role of stent-grafts in preventing future aortic rupture.

Для цитирования: Semba C P, Kato N, Kee S T, Lee G K, Mitchell R S, Miller D C, Dake M D. Acute rupture of the descending thoracic aorta: repair with use of endovascular stent-grafts.. Journal of vascular and interventional radiology : JVIR. 1997. DOI: 10.1016/s1051-0443(97)70568-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.