MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1121/1.3095803

Медицинская библиотека · The Journal of the Acoustical Society of America · 2009

Results of the National Institute for Occupational Safety and Health-U.S. Environmental Protection Agency interlaboratory comparison of American National Standards Institute S12.6-1997 Methods A and B.

Murphy William J, Byrne David C, Gauger Dan, Ahroon William A, Berger Elliott, Gerges Samir N Y, McKinley Richard, Witt Brad, Krieg Edward F

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

The National Institute for Occupational Safety and Health and the Environmental Protection Agency sponsored the completion of an interlaboratory study to compare two fitting protocols specified by ANSI S12.6-1997 (R2002) [(2002). American National Standard Methods for the Measuring Real-Ear Attenuation of Hearing Protectors, American National Standards Institute, New York]. Six hearing protection devices (two earmuffs, foam, premolded, custom-molded earplugs, and canal-caps) were tested in six laboratories using the experimenter-supervised, Method A, and (naive) subject-fit, Method B, protocols with 24 subjects per laboratory. Within-subject, between-subject, and between-laboratory standard deviations were determined for individual frequencies and A-weighted attenuations. The differences for the within-subject standard deviations were not statistically significant between Methods A and B. Using between-subject standard deviations from Method A, 3-12 subjects would be required to identify 6-dB differences between attenuation distributions. Whereas using between-subject standard deviations from Method B, 5-19 subjects would be required to identify 6-dB differences in attenuation distributions of a product tested within the same laboratory. However, the between-laboratory standard deviations for Method B were -0.1 to 3.0 dB less than the Method A results. These differences resulted in considerably more subjects being required to identify statistically significant differences between laboratories for Method A (12-132 subjects) than for Method B (9-28 subjects).

Для цитирования: Murphy William J, Byrne David C, Gauger Dan, Ahroon William A, Berger Elliott, Gerges Samir N Y, McKinley Richard, Witt Brad, Krieg Edward F. Results of the National Institute for Occupational Safety and Health-U.S. Environmental Protection Agency interlaboratory comparison of American National Standards Institute S12.6-1997 Methods A and B.. The Journal of the Acoustical Society of America. 2009. DOI: 10.1121/1.3095803.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.