Comparison of different diagnostic products for skin prick testing.

Pagani M, Antico A, Cilia M, Calabrò D, Poto S, Pecora S, Burastero S E

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Different in vivo methods are used to quantify the amount of allergens in products for skin prick testing. It is unclear how this impacts on the correct diagnosis of allergies.

AIM OF THE STUDY: We compared the allergenic potency of three commercial extracts for skin prick testing and evaluated batch-to-batch differences within each product.

METHODS

Patients with a mono-sensitization (specific IgE level > 0,70 KU/L, ImmunoCAP, Phadia) to Phleum pratense (N=21), Parietaria judaica (N=20) or Dermatophagoides pteronyssinus (N=28) were evaluated by standard skin prick testing and with the end-point dilution technique using commercial products from Stallergenes (A) (Antony, France), Lofarma Allergeni (B) (Milan, Italy) and ALK Abellò (C) (Hoersholm, Denmark). Results were expressed as mean areas of the wheal (cut-off for positive reactions: 7 mm2).

RESULTS

With standard prick testing, the following differences in wheal areas were found: Phleum, C higher than B (p=0.0454); Parietaria, C higher than A (p=0.094); Dermatophagoides, C higher than A (p=0.021). With limiting dilution testing, the following differences in dilutions yielding positive skin prick tests were found: Phleum, C and B higher than A (p=0.0391 and 0.0039, respectively); Dermatophagoides, C higher than A and B (p=0.0010 and 0.0156, respectively). In the batch-to-batch comparison, mean differences between wheal areas of compared undiluted solutions did not significantly differ in any allergen tested, although in single cases large differences were observed. At the 1 to 64 dilution, agreement was significant only with Dermatophagoides from Manufacturer C (p= 0.262). At the 1 to 16 dilution, agreement was significant with Phleum from Manufacturer C (p=0.0116) and with Dermatophagoides from Manufacturer B and C (p=0.0239 and 0.0001, respectively). At the 1 to 4 dilution agreement was significant with Dermatophagoides from the three considered Manufacturers (p=0.0189, 0.0052 and 0.0077, respectively) and with Phleum from Manufacturer B and C (p=0.0336 and 0.0113, respectively).

CONCLUSION

There are significant differences among commercially available diagnostic products for skin prick testing.

Для цитирования: Pagani M, Antico A, Cilia M, Calabrò D, Poto S, Pecora S, Burastero S E. Comparison of different diagnostic products for skin prick testing.. European annals of allergy and clinical immunology. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.