Electrodiagnosis of Guillain-Barre syndrome in the International GBS Outcome Study: Differences in methods and reference values.

Arends Samuel, Drenthen Judith, van den Bergh Peter, Franssen Hessel, Hadden Robert D M, Islam Badrul, Kuwabara Satoshi, Reisin Ricardo C, Shahrizaila Nortina, Amino Hiroshi, Antonini Giovanni, Attarian Shahram, Balducci Claudia, Barroso Fabio, Bertorini Tulio, Binda Davide, Brannagan Thomas H, Buermann Jan, Casasnovas Carlos, Cavaletti Guido, Chao Chi-Chao, Dimachkie Mazen M, Fulgenzi Ernesto A, Galassi Giuliana, Gutiérrez Gutiérrez Gerardo, Harbo Thomas, Hartung Hans-Peter, Hsieh Sung-Tsang, Kiers Lynette, Lehmann Helmar C, Manganelli Fiore, Marfia Girolama A, Mataluni Giorgia, Pardo Julio, Péréon Yann, Rajabally Yusuf A, Santoro Lucio, Sekiguchi Yukari, Stein Beth, Stettner Mark, Uncini Antonino, Verboon Christine, Verhamme Camiel, Vytopil Michal, Waheed Waqar, Wang Min, Zivkovic Sasha, Jacobs Bart C, Cornblath David R, IGOS consortium

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the heterogeneity of electrodiagnostic (EDx) studies in Guillain-Barré syndrome (GBS) patients collected as part of the International GBS Outcome Study (IGOS).

METHODS

Prospectively collected clinical and EDx data were available in 957 IGOS patients from 115 centers. Only the first EDx study was included in the current analysis.

RESULTS

Median timing of the EDx study was 7 days (interquartile range 4-11) from symptom onset. Methodology varied between centers, countries and regions. Reference values from the responding 103 centers were derived locally in 49%, from publications in 37% and from a combination of these in the remaining 15%. Amplitude measurement in the EDx studies (baseline-to-peak or peak-to-peak) differed from the way this was done in the reference values, in 22% of motor and 39% of sensory conduction. There was marked variability in both motor and sensory reference values, although only a few outliers accounted for this.

CONCLUSIONS

Our study showed extensive variation in the clinical practice of EDx in GBS patients among IGOS centers across the regions.

SIGNIFICANCE: Besides EDx variation in GBS patients participating in IGOS, this diversity is likely to be present in other neuromuscular disorders and centers. This underlines the need for standardization of EDx in future multinational GBS studies.

Для цитирования: Arends Samuel, Drenthen Judith, van den Bergh Peter, Franssen Hessel, Hadden Robert D M, Islam Badrul, Kuwabara Satoshi, Reisin Ricardo C, Shahrizaila Nortina, Amino Hiroshi, Antonini Giovanni, Attarian Shahram, Balducci Claudia, Barroso Fabio, Bertorini Tulio, Binda Davide, Brannagan Thomas H, Buermann Jan, Casasnovas Carlos, Cavaletti Guido, Chao Chi-Chao, Dimachkie Mazen M, Fulgenzi Ernesto A, Galassi Giuliana, Gutiérrez Gutiérrez Gerardo, Harbo Thomas, Hartung Hans-Peter, Hsieh Sung-Tsang, Kiers Lynette, Lehmann Helmar C, Manganelli Fiore, Marfia Girolama A, Mataluni Giorgia, Pardo Julio, Péréon Yann, Rajabally Yusuf A, Santoro Lucio, Sekiguchi Yukari, Stein Beth, Stettner Mark, Uncini Antonino, Verboon Christine, Verhamme Camiel, Vytopil Michal, Waheed Waqar, Wang Min, Zivkovic Sasha, Jacobs Bart C, Cornblath David R, IGOS consortium. Electrodiagnosis of Guillain-Barre syndrome in the International GBS Outcome Study: Differences in methods and reference values.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2022. DOI: 10.1016/j.clinph.2021.12.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.