MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euac042

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2022

Remote ECG monitoring to reduce complications following transcatheter aortic valve implantations: the Redirect TAVI study.

Natarajan Madhu Kailash, Sheth Tej Narendra, Wijeysundera Harindra Channa, Chavarria Jorge, Rodes-Cabau Josep, Velianou James Louis, Radhakrishnan Sam, Newman Toni, Smith Amanda, Wong Jorge Alfredo, Schwalm Jon David, Duong Monica, Mian Rajibul Islam, Bishop Marsella Giuliana, Healey Jeffrey Sean

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: The optimal strategy of monitoring for conduction disturbances in patients undergoing transcatheter aortic valve implantation (TAVI) is uncertain. We evaluated a pre- and post-TAVI remote ambulatory cardiac monitoring (rACM) strategy for identification of conduction disturbances and to reduce unplanned pre-discharge post-TAVI permanent pacemaker implantation (PPMI).

METHODS AND

RESULTS

REdireCT TAVI (NCT0381820) was a prospective cohort study of patients referred for outpatient TAVI. Patients with prior PPMI were excluded. Remote ambulatory cardiac monitoring consisted of 2 weeks of continuous electrocardiogram (ECG) monitoring (Pocket-ECGTM) both before and after TAVI. Compliance to monitoring, frequency of notifications, unplanned PPMI post-TAVI, and length of hospitalization were measured. Between June 2018 and March 2020, in 192 undergoing TAVI (mean age: 81.8 years; female sex 46%; balloon-expandable valve 95.3%), compliance to rACM was 91.7% pre-TAVI (mean duration: 12.8 days), and 87.5% post-TAVI (mean duration: 12.9 days). There were 24 (12.5%) rACM notifications (13 pre-TAVI; 11 post-TAVI) resulting in 14 (7.3%) planned PPMI: seven pre-TAVI [due to sinus pauses n = 2 or atrio-ventricular block (AVB) n = 5] and seven post-TAVI [due to sinus pauses n = 1 or AVB n = 5 or ventricular tachycardia (VT) n = 1]. In addition, nine (4.7%) patients received pre-TAVI PPMI due to high-risk baseline ECG (right bundle branch block with hemi-block or prolonged PR interval). Unplanned PPMI post-TAVI during index hospitalization occurred in six (3.1%) patients due to AVB and in one patient readmitted with AVB. The median length of stay post-TAVI was 1 day.

CONCLUSION

A strategy of routine rACM was feasible and frequently led to PPMI. Our approach of 2-week rACM both pre- and post-TAVI achieves both high patient compliance and sufficient surveillance.

CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT03810820.

Для цитирования: Natarajan Madhu Kailash, Sheth Tej Narendra, Wijeysundera Harindra Channa, Chavarria Jorge, Rodes-Cabau Josep, Velianou James Louis, Radhakrishnan Sam, Newman Toni, Smith Amanda, Wong Jorge Alfredo, Schwalm Jon David, Duong Monica, Mian Rajibul Islam, Bishop Marsella Giuliana, Healey Jeffrey Sean. Remote ECG monitoring to reduce complications following transcatheter aortic valve implantations: the Redirect TAVI study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2022. DOI: 10.1093/europace/euac042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.