OBJECTIVES

Sutureless aortic valve replacement (SU-SAVR) has been associated with higher rates of permanent pacemaker (PPM) compared with conventionally implanted aortic bioprostheses. The purpose of this study was to determine the incidence, predictors and mid-term prognostic impact of PPM after Perceval (Livanova, London, UK) SU-SAVR in low-risk patients.

METHODS

A total of 400 consecutive low-risk (EuroSCORE II < 4%) patients without prior pacemaker who underwent surgical aortic valve replacement with the Perceval prosthesis from 2013 to 2019 in 2 centres were included. Baseline, clinical and electrocardiographic parameters, procedural characteristics and follow-up data were collected.

RESULTS

PPM was required in 36 (9%) patients after SU-SAVR, with a median time between the procedure and PPM implantation of 7.5 (4.5-10.5) days. Older age and prior right bundle branch block (RBBB) were associated with an increased risk of PPM (P < 0.05 for all), but only baseline RBBB was found to be an independent predictor of new PPM requirement (odds ratio: 2.60, 95% confidence interval: 1.15-5.81; P = 0.022). At a median follow-up of 3.4 (2.3-4.5) years, there were no differences between groups in mortality (PPM: 36%, no PPM: 22%, P = 0.105) or heart failure rehospitalization (PPM: 25%, no PPM: 21%, P = 0.839).

CONCLUSIONS

About 1 out of 10 low-risk patients with aortic stenosis undergoing SU-SAVR with the Perceval prosthesis required PPM implantation. Prior RBBB determined an increased risk (close to 3-fold) of PPM following the procedure. PPM was not associated with a higher risk of clinical events at 3-year follow-up.

Для цитирования: Vilalta Victoria, Cediel Germán, Mohammadi Siamak, López Helena, Kalavrouziotis Dimitri, Resta Helena, Dumont Eric, Voisine Pierre, Philippon François, Escabia Claudia, Borrellas Andrea, Alperi Alberto, Bayes-Genis Antoni, Rodes-Cabau Josep. Incidence, predictors and prognostic value of permanent pacemaker implantation following sutureless valve implantation in low-risk aortic stenosis patients.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2022. DOI: 10.1093/ejcts/ezac307.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.