MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjcr/ytac129

Медицинская библиотека · European heart journal. Case reports · 2022

Ventricular premature complexes successfully ablated from the non-coronary cusp: a case report.

Tanaka Atsushi, Nozoe Masatsugu, Tsutsumi Takaki, Kubota Toru

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ventricular premature complexes (VPCs) occasionally originate from the aortic sinus of Valsalva. Because the anterior part of the left coronary cusp (LCC) and right coronary cusp (RCC) are connected through the ventricular musculature at their bases, VPCs are more common in the LCC and the RCC than in the non-coronary cusp (NCC). We herein report a case in which VPCs were successfully ablated from the NCC, which is considered rare.

CASE SUMMARY: A 30-year-old woman was admitted to our hospital for the ablation of VPCs, which comprised 43% of the total heart beats. The clinical VPCs had an inferior axis and left bundle branch block morphology with a precordial transition between V4 and V5. Three-dimensional mapping of the target VPCs indicated that the earliest activation site was RCC. After radiofrequency (RF) energy application at the RCC, VPCs were temporally suppressed but recurred after 24 min. Remapping of the recurrent VPCs revealed that the earliest activation site shifted from the RCC to the His region. To avoid the risk of atrioventricular block, RF energy was applied from the NCC, which resulted in successful elimination of the VPCs without any complications.

DISCUSSION: The present case suggests that RF energy application from the NCC may be a safe and effective option for the ablation of VPCs with the earliest activation at the RCC and His region.

Для цитирования: Tanaka Atsushi, Nozoe Masatsugu, Tsutsumi Takaki, Kubota Toru. Ventricular premature complexes successfully ablated from the non-coronary cusp: a case report.. European heart journal. Case reports. 2022. DOI: 10.1093/ehjcr/ytac129.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.