DOI 10.1016/j.hrthm.2022.03.1222

Медицинская библиотека · Heart rhythm · 2022

Atrioventricular junction ablation in patients with conduction system pacing leads: A comparison of His-bundle vs left bundle branch area pacing leads.

Pillai Ajay, Kolominsky Jeffrey, Koneru Jayanthi N, Kron Jordana, Shepard Richard K, Kalahasty Gautham, Huang Weijian, Verma Atul, Ellenbogen Kenneth A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Single-center studies have shown feasibility of conduction system pacing (CSP) via His-bundle pacing (HBP) or left bundle branch area pacing (LBBAP) in atrial fibrillation (AF) patients undergoing atrioventricular junction ablation (AVJA).

OBJECTIVE

The purpose of this study was to compare outcomes in patients with HBP and LBBAP leads undergoing AVJA.

METHODS

Consecutive patients with CSP leads referred for AVJA between October 2014 and May 2021 were included. Pacing lead characteristics, procedural characteristics, complications, and long-term outcomes were assessed.

RESULTS

One hundred five AVJA procedures (55 HBP, 50 LBBAP) were performed in 98 patients (48 HBP, 50 LBBAP). The acute success rate of the AVJA procedure was 94% vs 100% (P = .11) in HBP vs LBBAP groups. Seven (14%) redo AVJA procedures were required in the HBP group. Mean procedural time (44 ± 24 min vs 34 ± 16 min; P = .02) and mean fluoroscopy time (16 ± 18 min vs 7 ± 6 min; P <.001) were significantly longer in the HBP vs LBBAP group. An acute rise in threshold was noted in 8 cases (14.5%), and 4 (8%) developed exit block after AVJA in HBP patients. Chronic HBP threshold ≥2.5 V was seen in 23 patients (48%), and 4 (8%) HBP leads were deactivated. CSP preserved ejection fraction (EF) in the overall cohort (N = 70; 53% ± 10% vs 55% ± 10%; P = .09) and significantly improved in those with reduced EF <50% at baseline (N = 16; 37% ± 7.6% vs 46% ± 13%; P = .02).

CONCLUSION

AVJA in the presence of an LBBAP lead is associated with a higher success rate and fewer acute and chronic lead-related complications. CSP with either HBP or LBBAP preserves left ventricular systolic function in patients with refractory atrial fibrillation post AVJA.

Для цитирования: Pillai Ajay, Kolominsky Jeffrey, Koneru Jayanthi N, Kron Jordana, Shepard Richard K, Kalahasty Gautham, Huang Weijian, Verma Atul, Ellenbogen Kenneth A. Atrioventricular junction ablation in patients with conduction system pacing leads: A comparison of His-bundle vs left bundle branch area pacing leads.. Heart rhythm. 2022. DOI: 10.1016/j.hrthm.2022.03.1222.