MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.shj.2022.100019

Медицинская библиотека · Structural heart : the journal of the Heart Team · 2022

Conduction Disturbance, Pacemaker Rates, and Hospital Length of Stay Following Transcatheter Aortic Valve Implantation with the Sapien 3 Valve.

Isogai Toshiaki, Shekhar Shashank, Saad Anas M, Abdelfattah Omar M, Tarakji Khaldoun G, Wazni Oussama M, Kalra Ankur, Yun James J, Krishnaswamy Amar, Reed Grant W, Kapadia Samir R, Puri Rishi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In the absence of randomized data, an expert panel recently proposed an algorithm for conduction disturbance management in transcatheter aortic valve implantation (TAVI) recipients. However, external validations of its recommendations are limited.

METHODS

We retrospectively identified 808 patients without a pre-existing pacing device who underwent transfemoral TAVI with the Sapien 3 valve at our institution in 2018-2019. Patients were grouped based on pre-existing conduction disturbance and immediate post-TAVI electrocardiogram. Timing of temporary pacemaker (TPM) removal and hospital discharge were compared with those of the expert panel recommendations to evaluate the associated risk of TPM reinsertion and permanent pacemaker (PPM) implantation.

RESULTS

In most group 1 patients (no electrocardiogram changes without pre-existing right bundle branch block), the timing of TPM removal and discharge were concordant with those of the expert panel recommendations, with low TPM reinsertion (0.8%) and postdischarge PPM (0.8%) rates. In the majority of group 5 patients (procedural high-degree/complete atrioventricular block), TPM was maintained, followed by PPM implantation, compatible with the expert panel recommendations. In contrast, in groups 2-4 (pre-existing/new conduction disturbances), earlier TPM removal than recommended by the expert panel (mostly, immediately after procedure) was feasible in 97.5%-100% of patients, with a low TPM reinsertion rate (0.0%-1.8%); earlier discharge was also feasible in 50.0%-65.5%, with a low 30-day postdischarge PPM rate (0.0%-2.8%) and no 30-day death.

CONCLUSIONS

Early TPM removal and discharge after TAVI appear safe and feasible in the majority of cases. These data may provide a framework for an early, streamlined hospital discharge plan for TAVI recipients, optimizing both cost savings and patient safety.

Для цитирования: Isogai Toshiaki, Shekhar Shashank, Saad Anas M, Abdelfattah Omar M, Tarakji Khaldoun G, Wazni Oussama M, Kalra Ankur, Yun James J, Krishnaswamy Amar, Reed Grant W, Kapadia Samir R, Puri Rishi. Conduction Disturbance, Pacemaker Rates, and Hospital Length of Stay Following Transcatheter Aortic Valve Implantation with the Sapien 3 Valve.. Structural heart : the journal of the Heart Team. 2022. DOI: 10.1016/j.shj.2022.100019.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.