MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2298/sarh1406286m

Медицинская библиотека · Srpski arhiv za celokupno lekarstvo · 2014

Changes in the retrobulbar hemodynamic parameters after decreasing the elevated intraocular pressure in primary open-angle glaucoma patients.

Marjanović Ivan, Martinez Antonio, Marjanović Marija, Milić Natasa, Kontić Djordje, Hentova-Senćanić Paraskeva, Marković Vujica, Bozić Marija

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Ocular blood flow (OBF) disturbances could be involved both in the pathogenesis and in progression of glaucomatous damage.

OBJECTIVE

The aim of the study was to compare the retrobulbar hemodynamic parameters in the ophthalmic artery (OA), central retinal artery (CRA) and short posterior cilliary arteries (SPCA) after decreasing the elevated intraocular pressure (IOP) in primary open-angle glaucoma (POAG) patients by using color Doppler imaging (CDI).

METHODS

We examined 60 patients (21 male and 39 female) with diagnosed and treated POAG. Thirty-nine patients had increased IOP (> 25 mm Hg). Peak-systolic velocity (PSV), end-diastolic velocity (EDV), Pourcelot resistance index (RI), and pulsatility index (PI) were assessed in the OA, CRA, and SPCA. IOP was measured both with the Goldmann Applanation tonometer (GAT) and with the Dynamic Contour tonometer (DCT), three times respectively. Ocular pulse amplitude (OPA) was measured using DCT.

RESULTS

The retrobulbar parameters between the baseline and after IOP reduction showed no difference in measurements. After Bonferroni correction (p < or = 0.0056, alpha/9) statistical significance was recorded only in the following retrobulbar hemodynamic parameters; DCT (29.8 +/- 6.2 vs. 15.5 +/- 5.0), GAT (33.8 +/- 9.0 vs. 15.0 +/- 6.6) and OPA measurements (4.3 +/- 1.0 vs. 3.0 +/- 1.6), as compared to the baseline. There was no correlation between the changes in IOP measured with either DCT or GAT and changes in the hemodynamic parameters (p > 0.05 for all). Pearson correlation coefficient (95% CI) showed very good correlation for IOP measurements between DCT and GAT: at baseline 0.83 (0.71 to 0.90) and at the end 0.71 (0.55 to 0.83); p < 0.0001 for both measurements, but without any difference between them (p > 0.05).

CONCLUSION

There was a lack of correlation between the changes in IOP measured with either DCT or GAT and the changes in the hemodynamic parameters.

Для цитирования: Marjanović Ivan, Martinez Antonio, Marjanović Marija, Milić Natasa, Kontić Djordje, Hentova-Senćanić Paraskeva, Marković Vujica, Bozić Marija. Changes in the retrobulbar hemodynamic parameters after decreasing the elevated intraocular pressure in primary open-angle glaucoma patients.. Srpski arhiv za celokupno lekarstvo. 2014. DOI: 10.2298/sarh1406286m.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.