Efficacy of SLO-Microperimetry and Humphrey for evaluating macular sensitivity changes in advanced glaucoma.

Kulkarni Sadhana V, Coupland Stuart G, Stitt David M, Hamilton John, Brownstein Jonathan J, Damji Karim F

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the efficacy of scanning laser ophthalmoscope microperimetry (SLO-MP) and Humphrey visual fields in detecting macular sensitivity changes in advanced glaucoma.

DESIGN

Prospective cohort study.

PARTICIPANTS

25 patients with advanced primary open angle glaucoma and 2 consecutive abnormal Humphrey 10-2 SITA Standard visual field tests.

METHODS

Thirty-six eyes of 25 patients with 2 consecutive abnormal Humphrey 10-2 SITA Standard (H10) visual fields were retested with a modified 10-2 SLO-MP within 3 months of the last reliable H10. A standardized grid was used to mark the macula. Primary outcome was change in mean macular sensitivity (dB; H10 and SLO-MP) in relation to mean macular retinal nerve fibre layer (RNFL) thickness (µm) by SLO- optical coherence tomography (SLO-OCT). Secondary outcome was comparison of reliability indices for both tests. Linear regression was used for analysis.

RESULTS

Mean macular sensitivity was significantly lower in SLO-MP (9.33 ± 3.37 dB) than H10 (18.83 ± 6.46 dB; p < 0.0001). Mean macular RNFL thickness correlated significantly with retinal sensitivity by both SLO-MP (r = 0.39, p < 0.02) and H10 (r = 0.37, p < 0.03). Fixation losses were better controlled in SLO-MP (0.38 ± 1.1) than H10 (4.28 ± 7.9; p = 0.008). False-positive responses were similar (SLO-MP: 2.25 ± 4.53, H10: 1.78 ± 3.33; p = 0.80). A statistically significant difference was noted in the false-negative responses (SLO-MP: 26.87 ± 25.24, H10: 5.33 ± 9.70; p < 0.0001).

CONCLUSIONS

Macular sensitivity determined by both H10 and SLO-MP correlates significantly with mean macular RNFL thickness measured by SLO-OCT. Precise localization of the macula in SLO-MP results in lower fixation losses. Detection of denser field defects by SLO-MP results in higher false-negative responses. A larger sample size is needed to further study the value of this diagnostic tool.

Для цитирования: Kulkarni Sadhana V, Coupland Stuart G, Stitt David M, Hamilton John, Brownstein Jonathan J, Damji Karim F. Efficacy of SLO-Microperimetry and Humphrey for evaluating macular sensitivity changes in advanced glaucoma.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2013. DOI: 10.1016/j.jcjo.2013.08.001.