MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40644-024-00699-3

Медицинская библиотека · Cancer imaging : the official publication of the International Cancer Imaging Society · 2024

Head-to-head comparison of [68Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT for the evaluation of tonsil cancer and lymph node metastases: a single-centre retrospective study.

Ji Mengjing, Ma Guang, Liu Cheng, Gu Bingxin, Du Xinyue, Ou Xiaomin, Xu Xiaoping, Song Shaoli, Yang Zhongyi

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

This study aimed to compare the diagnostic value of [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT imaging for primary lesions and metastatic lymph nodes in patients with tonsil cancer.

METHOD: Twenty-one tonsil cancer patients who underwent [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT scans within two weeks in our centre were retrospectively enrolled. The maximum standardized uptake value (SUVmax) and tumor-to-background ratio (TBR) of the two tracers were compared by using the Mann‒Whitney U test. In addition, the sensitivity, specificity, and accuracy of the two methods for diagnosing metastatic lymph nodes were analysed.

RESULTS

In detecting primary lesions, the efficiency was higher for [68 Ga]Ga-DOTA-FAPI-04 PET/CT (20/22) than for [18F]FDG PET/CT (9/22). Although [68 Ga]Ga-DOTA-FAPI-04 uptake (SUVmax, 5.03 ± 4.06) was lower than [18F]FDG uptake (SUVmax, 7.90 ± 4.84, P = 0.006), [68 Ga]Ga-DOTA-FAPI-04 improved the distinction between the primary tumor and contralateral normal tonsillar tissue. The TBR was significantly higher for [68 Ga]Ga-DOTA-FAPI-04 PET/CT (3.19 ± 2.06) than for [18F]FDG PET/CT (1.89 ± 1.80) (p < 0.001). In lymph node analysis, SUVmax and TBR were not significantly different between [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT (7.67 ± 5.88 vs. 8.36 ± 6.15, P = 0.498 and 5.56 ± 4.02 vs. 4.26 ± 3.16, P = 0.123, respectively). The specificity and accuracy of [68 Ga]Ga-DOTA-FAPI-04 PET/CT were higher than those of [18F]FDG PET/CT in diagnosing metastatic cervical lymph nodes (all P < 0.05).

CONCLUSION

The availability of [68 Ga]Ga-DOTA-FAPI-04 complements the diagnostic results of [18F]FDG by improving the detection rate of primary lesions and the diagnostic accuracy of cervical metastatic lymph nodes in tonsil cancer compared to [18F]FDG.

Для цитирования: Ji Mengjing, Ma Guang, Liu Cheng, Gu Bingxin, Du Xinyue, Ou Xiaomin, Xu Xiaoping, Song Shaoli, Yang Zhongyi. Head-to-head comparison of [68Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT for the evaluation of tonsil cancer and lymph node metastases: a single-centre retrospective study.. Cancer imaging : the official publication of the International Cancer Imaging Society. 2024. DOI: 10.1186/s40644-024-00699-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.