MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2023-081050

Медицинская библиотека · BMJ open · 2024

Clinical decision support system based on deep learning for evaluating implantable collamer lens size and vault after implantable collamer lens surgery: a retrospective study.

Yang Yixuan, Long Zhengqin, Lei Bo, Liu Wei, Ye Jian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To aid doctors in selecting the optimal preoperative implantable collamer lens (ICL) size and to enhance the safety and surgical outcomes of ICL procedures, a clinical decision support system (CDSS) is proposed in our study.

DESIGN

A retrospective study of patients after ICL surgery.

SETTING

China Tertiary Myopia Prevention and Control Center.

PARTICIPANTS

2772 eyes belonging to 1512 patients after ICL surgery. Data were collected between 2018 and 2022.

OUTCOME MEASURES: A CDSS is constructed and used to predict vault at 1 month postoperatively and preoperative ICL dimensions using various artificial intelligence methods. Accuracy metrics as well as area under curve (AUC) parameters are used to determine the CDSS prediction methods.

RESULTS

Among the ICL size prediction models, conventional neural networks (CNNs) achieve the best prediction accuracy at 91.37% and exhibit the highest AUC of 0.842. Regarding the prediction model for vault values 1 month after surgery, CNN surpasses the other methods with an accuracy of 85.27%, which has the uppermost AUC of 0.815. Thus, we select CNN as the prediction algorithm for the CDSS.

CONCLUSIONS

This study introduces a CDSS to assist doctors in selecting the optimal ICL size for patients while improving the safety and postoperative outcomes of ICL surgery.

Для цитирования: Yang Yixuan, Long Zhengqin, Lei Bo, Liu Wei, Ye Jian. Clinical decision support system based on deep learning for evaluating implantable collamer lens size and vault after implantable collamer lens surgery: a retrospective study.. BMJ open. 2024. DOI: 10.1136/bmjopen-2023-081050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.