MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_1018_23

Медицинская библиотека · Indian journal of ophthalmology · 2024

Visual performance and patient satisfaction with AcrySof® IQ Vivity® IOL: Experience from a tertiary care center in central India.

Bhasin Purendra, Sarkar Deepayan, Bhasin Priyamvada, Dhanapal Praveen P, Ubhal Gopal N, Bhargava Meenu

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study the visual outcomes and patient satisfaction profile among patients post phacoemulsification with the Vivity intraocular lens (IOL) implantation.

METHOD: This was a hospital-based, prospective, observational study cons isting of 64 study subjects who were followed up for 1 month to look for the objective and subjective aspects of visual outcomes of Vivity IOLs. Objective parameters included distance vision, intermediate vision, near vision, and contrast-sensitivity, whereas subjective parameters were assessed using the modified Catquest 9SF Questionnaire.

RESULTS

Among the total study population, 82.5% were males and 17.5% were females, the most common age group was 41-50 years. In addition, 93.6% had a distance visual acuity of 6/9 or better, 93.7% had an intermediate vision of N18 or better, whereas 50.8% had a near vision of N18 or better. Good contrast sensitivity was reported among 79.4% of subjects, and 95.2% of study subjects were comfortable with distance vision, whereas 74.6% and 22.2% were comfortable with intermediate and near vision, respectively. Only two patients complained of glare, whereas none complained of halos and starbursts. A total of 88.8% of study subjects were satisfied with their postoperative visual outcomes, whereas 87.3% were willing to Vivity IOL in the other eye or were willing to refer this IOL to others.

CONCLUSION

The study demonstrated a good distance and intermediate visual acuity post-Vivity IOL implantation, whereas near activities mostly required the use of near-addition glasses, though requiring lesser near-addition power.

Для цитирования: Bhasin Purendra, Sarkar Deepayan, Bhasin Priyamvada, Dhanapal Praveen P, Ubhal Gopal N, Bhargava Meenu. Visual performance and patient satisfaction with AcrySof® IQ Vivity® IOL: Experience from a tertiary care center in central India.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_1018_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.