MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2019.12.007

Медицинская библиотека · American heart journal · 2019

Clinical outcomes for chest pain patients discharged home from emergency departments using high-sensitivity versus conventional cardiac troponin assays.

Lau Geoffrey, Koh Maria, Kavsak Peter A, Schull Michael J, Armstrong David W J, Udell Jacob A, Austin Peter C, Wang Xuesong, Ko Dennis T

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

High-sensitivity cardiac troponin (hs-cTn) assays enhance detection of lower circulating troponin concentrations, but the impact on outcomes in clinical practice is unclear. Our objective was to compare outcomes of chest pain patients discharged from emergency departments (EDs) using hs-cTn and conventional troponin (cTn) assays.

METHODS

We conducted an observational study of chest pain patients aged 40-105 years who presented to an ED from April 1, 2013, to March 31, 2017, and were discharged home. We compared 30-day and 1-year outcomes of EDs that used hs-cTn versus cTn assays. The primary outcome was a composite of all-cause death, myocardial infarction or unstable angina. Comparisons were conducted with (1) no adjustment; (2) adjustment for demographic, socioeconomic, and hospital characteristics; and (3) full clinical adjustment.

RESULTS

Among the 394,910 patients, 62,138 (15.7%) were evaluated at hs-cTn EDs and 332,772 (84.3%) were evaluated at cTn EDs. Patients discharged from hs-cTn EDs were less likely to have diabetes, hypertension, or prior heart disease. At 30 days, the unadjusted primary outcome rate was lower in hs-cTn EDs (0.9% vs 1.0%, P < .001). The 30-day hazard ratios for the primary outcome were 0.84 (95% CI 0.77-0.92) for no adjustment and 0.98 (95% CI 0.88-1.08) for full adjustment. Over 1 year, patients discharged from hs-cTn EDs had significantly fewer primary outcomes (3.7% vs 4.1%, P < .001) and lower hazard ratio (0.93; 95% CI 0.89-0.98) even after full adjustment.

CONCLUSIONS

Hs-cTn testing was associated with a significantly lower adjusted hazard of myocardial infarction, angina, and all-cause hospitalization at 1 year but not 30 days.

Для цитирования: Lau Geoffrey, Koh Maria, Kavsak Peter A, Schull Michael J, Armstrong David W J, Udell Jacob A, Austin Peter C, Wang Xuesong, Ko Dennis T. Clinical outcomes for chest pain patients discharged home from emergency departments using high-sensitivity versus conventional cardiac troponin assays.. American heart journal. 2019. DOI: 10.1016/j.ahj.2019.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.