MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2017.01.012

Медицинская библиотека · Journal of cataract and refractive surgery · 2017

Toric outcomes: Computer-assisted registration versus intraoperative aberrometry.

Solomon Jonathan D, Ladas John

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare refractive outcomes of intraoperative computer-assisted registration and intraoperative aberrometry for the reduction of cylinder during toric intraocular lens (IOL) placement.

SETTING

Bowie Vision Institute, Bowie, Maryland, USA.

DESIGN

Prospective randomized case series.

METHOD: The patients were divided into 2 groups that had toric IOL implantation after phacoemulsification. The intraoperative computer-assisted registration group (Group 1) had preoperative toric calculations. The aberrometry group (Group 2) was guided by a vergence formula and intraoperative pseudophakic cylindrical measurements to determine the final IOL power and intended orientation. The primary outcome measure was the mean postoperative remaining refractive astigmatism, and it was compared with the predicted amount of cylindrical correction with the IOL.

RESULTS

Fifty-two patients (104 eyes) had sequential cataract surgery. The mean amount of cylinder correction was 1.60 diopters (D) ± 0.70 (SD) (range 0.75 to 3.08 D) in Group 1 and 1.74 ± 0.79 D (range 0.72 to 3.08 D) in Group 2. The mean remaining refractive astigmatism was -0.29 ± 0.22 D in Group 1 and -0.46 ± 0.25 D in Group 2 (P = .0003). A difference vector of 0.1 @ 87 degrees (0.31 D arithmetic mean) was calculated in Group 1 and 0.0 @ 82 degrees (0.44 D arithmetic mean) in Group 2. The correction index was 1.03 in Group 1 and 0.95 in Group 2.

CONCLUSION

Intraoperative markerless computer-assisted registration and biometric guidance summarily yielded less remaining refractive cylinder than toric IOL placement guided by intraoperative aberrometry.

Для цитирования: Solomon Jonathan D, Ladas John. Toric outcomes: Computer-assisted registration versus intraoperative aberrometry.. Journal of cataract and refractive surgery. 2017. DOI: 10.1016/j.jcrs.2017.01.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.