MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtherbio.2025.104199

Медицинская библиотека · Journal of thermal biology · 2025

Validation of a novel method to quantify local axilla sweating, SweatSENSE.

McGill Andrew, Tinley Emmett Cullen, Edwards Stephanie E, Jamieson Andrew, Ford Jane, Winterton Evie, Shardey Jacob, Hand Rachel A, Efstathiou Spyridon, Wemyss Alan M, Grypioti Maria, Kirby Gavin, Barlow Tammie, Haddleton David M, Low David A

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

The aim of this study was to validate the ability of the novel SweatSENSE technique to measure local axilla sweating. The local axilla sweating responses to a range of physical activities were measured in 30 healthy females (28 ± 5 yr, 163 ± 7 cm; 62 ± 9 kg). Participants completed low-to moderate-intensity treadmill walking, stepping, and cycling in a 3-h protocol. Left axilla sweating was intermittently recorded using the novel SweatSENSE method, in which non-hydrochromic sweat-responsive paper sensors with PCDA polymer were placed in the axilla vault for 5 s. The sensors were analysed for the proportional colour change as an index of instantaneous local sweating. Percentage total sweat coverage (%TC) of the patches was determined. Ipsilateral axilla sweating was continuously recorded using capacitance hygrometry (CH). Intraclass correlation coefficient (ICC) analyses was used to examine the agreement between the CH and SweatSENSE %TC data for each participant. Heart rate, core and skin temperatures, ratings of perceived exertion (RPE) and thermal discomfort were also recorded. Heart rate (100 ± 25 beats.min-1, P < 0.05) and Tcore increased during the protocol (37.82 ± 0.23 °C, P < 0.05). Thermal discomfort increased from 'neutral' to 'warm' and RPE increased to 'somewhat hard' during the protocol (both P < 0.05). Local axilla sweating (CH and the SweatSENSE method) increased during each physical activity bout and progressively throughout the protocol (both P < 0.05). Twenty one out of thirty participants demonstrated significant ICC between axilla SweatSENSE and capacitance hygrometry sweating data [average (95 % confidence intervals] ICC; 0.483 (0.191-0.713)) indicating a moderate agreement between SweatSENSE and capacitance hygrometry, suggesting a moderate level of validity of the SweatSENSE method.

Для цитирования: McGill Andrew, Tinley Emmett Cullen, Edwards Stephanie E, Jamieson Andrew, Ford Jane, Winterton Evie, Shardey Jacob, Hand Rachel A, Efstathiou Spyridon, Wemyss Alan M, Grypioti Maria, Kirby Gavin, Barlow Tammie, Haddleton David M, Low David A. Validation of a novel method to quantify local axilla sweating, SweatSENSE.. Journal of thermal biology. 2025. DOI: 10.1016/j.jtherbio.2025.104199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.