DOI 10.1097/icb.0000000000000324

Медицинская библиотека · Retinal cases & brief reports · 2017

STRUCTURAL AND FUNCTIONAL CHARACTERIZATION OF BENIGN FLECK RETINA USING MULTIMODAL IMAGING.

Neriyanuri Srividya, Rao Chetan, Raman Rajiv

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report structural and functional features in a case series of benign fleck retina using multimodal imaging.

METHODS

Four cases with benign fleck retina underwent complete ophthalmic examination that included detailed history, visual acuity, and refractive error testing, FM-100 hue test, dilated fundus evaluation, full field electroretinogram, fundus photography with autofluorescence, fundus fluorescein angiography, and swept-source optical coherence tomography.

RESULTS

Age group of the cases ranged from 19 years to 35 years (3 males and 1 female). Parental consanguinity was reported in two cases. All of them were visually asymptomatic with best-corrected visual acuity of 20/20 (moderate astigmatism) in both the eyes. Low color discrimination was seen in two cases. Fundus photography showed pisciform flecks which were compactly placed on posterior pole and were discrete, diverging towards periphery. Lesions were seen as smaller dots within 1500 microns from fovea and were hyperfluorescent on autofluorescence. Palisading retinal pigment epithelium defects were seen in posterior pole on fundus fluorescein angiography imaging; irregular hyper fluorescence was also noted. One case had reduced cone responses on full field electroretinogram; the other three cases had normal electroretinogram. On optical coherence tomography, level of lesions varied from retinal pigment epithelium, inner segment to outer segment extending till external limiting membrane.

CONCLUSION

Functional and structural deficits in benign fleck retina were picked up using multimodal imaging.

Для цитирования: Neriyanuri Srividya, Rao Chetan, Raman Rajiv. STRUCTURAL AND FUNCTIONAL CHARACTERIZATION OF BENIGN FLECK RETINA USING MULTIMODAL IMAGING.. Retinal cases & brief reports. 2017. DOI: 10.1097/icb.0000000000000324.