DOI 10.1111/vsu.13971

Медицинская библиотека · Veterinary surgery : VS · 2023

Reliability of fluoroscopic examination of nasopharyngeal dorsoventral dimension change in pugs and French bulldogs.

Vodnarek Jakub, Vali Yasamin, Dupré Gilles, Dolezal Marlies, Lyrakis Manolis, Ludewig Eberhard

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare intra- and interobserver agreements in two-dimensional measurements of changes in nasopharyngeal dimensions during breathing in pugs and French bulldogs.

STUDY

DESIGN

Experimental randomized study.

ANIMALS: A total of 20 French bulldogs and 16 pugs.

METHODS

Four observers with different levels of experience measured the dorsoventral dimensions of the nasopharynx during inspiration and expiration on fluoroscopy videos. Measurements were performed at the maximal narrowing of the nasopharynx for the functional method and at the level of the tip of the epiglottis for the anatomically adjusted method. The intra- and interobserver agreements of the measurements, ratio of the dynamic nasopharyngeal change (ΔL), and grade of nasopharyngeal (NP) collapse (no, partial or complete) were evaluated.

RESULTS

The functional method resulted in intraobserver correlation coefficients of 0.532 (p < .01) and 0.751 (p < .01) and interobserver correlation coefficients of 0.378 (p < .01) and 0.621 (p < .01) for NP collapse grade and ΔL, respectively. The anatomically adjusted method, 0.491 (p < .01) and 0.576 (p < .01) and 0.495 (p < .01) and 0.729 (p < .01) for NP collapse grade and ΔL, respectively, were being used. One observer (radiologist) achieved intraobserver correlation coefficients >0.9 for both methods.

CONCLUSION

Fair interobserver agreement was found for NP collapse grade (functional method), moderate intra- and interobserver agreements were found for NP collapse grade and ΔL (both methods) while intraobserver agreement for ΔL was good (functional method).

CLINICAL SIGNIFICANCE: Both methods seem repeatable and reproducible but only for experienced radiologists. The use of ΔL may offer higher repeatability and reproducibility than grade of NP collapse regardless of the method used.

Для цитирования: Vodnarek Jakub, Vali Yasamin, Dupré Gilles, Dolezal Marlies, Lyrakis Manolis, Ludewig Eberhard. Reliability of fluoroscopic examination of nasopharyngeal dorsoventral dimension change in pugs and French bulldogs.. Veterinary surgery : VS. 2023. DOI: 10.1111/vsu.13971.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.