MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18240/ijo.2016.11.11

Медицинская библиотека · International journal of ophthalmology · 2016

Comparison of iris-fixated foldable lens and scleral-fixated foldable lens implantation in eyes with insufficient capsular support.

Zhang Han, Zhao Jun, Zhang Li-Jun, Liu Jing, Liu Yuan, Song Wei, Tian Qing-Fen, Wang Qi, Hamilton David-Rex

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To compare the outcomes of vision using two different intraocular lens (IOL) replacement techniques, iris-fixated foldable intraocular lens (IF-IOL) and scleral-fixated foldable intraocular lens (SF-IOL) in patients with insufficient capsular support.

METHODS

Total 63 eyes (62 patients) with insufficient posterior capsule support underwent replacement of IF-IOL or SF-IOL between January 2008 and August 2011. Outcome measures included changes in visual acuity, slit lamp examination, refractive indices and corneal curvatures.

RESULTS

The mean improvement of uncorrected visual acuity (UCVA) was greater in IF-IOL group compared to the SF-IOL group (0.43 D±0.19 D vs 0.35 D±0.18 D, P<0.05). Moreover, 12 (38.71%) eyes in IF-IOL group and 4 (12.50%) in SF-IOL group had a higher postoperative UCVA than preoperative best corrected visual acuity (BCVA) while 9 (29.03%) eyes in IF-IOL group and 18 (56.25%) in SF-IOL group had a lower postoperative UCVA than preoperative BCVA. The myopic mean manifest sphere and mean cylinder magnitude were lower in the IF-IOL group than that in the SF-IOL group (-0.47 D±0.58 D vs 0.50 D±0.43 D, P<0.01; 0.84 D±0.53 D vs 1.23 D±0.70 D, P<0.05). No difference of corneal astigmatism and surgically induced astigmatism was found between the two groups. In addition, fewer complications were observed in IF-IOL eyes.

CONCLUSION

IF-IOL implantation can give a significant improvement in vision with fewer complications than SF-IOL in patients with insufficient capsular support.

Для цитирования: Zhang Han, Zhao Jun, Zhang Li-Jun, Liu Jing, Liu Yuan, Song Wei, Tian Qing-Fen, Wang Qi, Hamilton David-Rex. Comparison of iris-fixated foldable lens and scleral-fixated foldable lens implantation in eyes with insufficient capsular support.. International journal of ophthalmology. 2016. DOI: 10.18240/ijo.2016.11.11.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.