PURPOSE: This study was initiated to introduce the term non-corneal ocular residual astigmatism (N-CORA) as a new parameter in astigmatic change analysis after implantation of two different types of non-toric, multifocal intraocular lenses (MIOL).

METHODS

Seventy-two eyes from 72 consecutive patients after MIOL surgery were studied in terms of a retrospective, cross-sectional data analysis. Two types of spherical MIOL were used. Surgical technique in all patients was a 2.4-mm incision phacoemulsification, performed by one surgeon. To investigate the magnitude and axis of astigmatic changes, the true corneal astigmatism and Alpins vector method were applied.

RESULTS

There were no statistically significant between-group differences related to the preoperative refraction or ocular residual astigmatism (ORA). After surgery, the mean refractive surgically induced astigmatism (RSIA) and the topographic SIA (TSIA) did not differ significantly between the lenses. The magnitude and orientation of ORA and N-CORA changed after surgery.

CONCLUSIONS

There are no statistically significant differences in postoperative ORA in magnitude or axis when implanting different types of MIOL. The similarity of N-CORA between both MIOL types shows that both diffractive and refractive asymmetric MIOLs with plate haptics have the same pseudolentogenic astigmatic effect which could be presented in terms of the newly introduced parameter N-CORA.

Для цитирования: Frings Andreas, Steinberg Johannes, Druchkiv Vasyl, Linke Stephan J, Katz Toam. Pseudolentogenic astigmatic effect of multifocal intraocular lenses: non-corneal ocular residual astigmatism (N-CORA) as a new parameter in astigmatic change analysis.. International ophthalmology. 2016. DOI: 10.1007/s10792-016-0359-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.