DOI 10.1161/01.cir.0000120703.99433.1e

Медицинская библиотека · Circulation · 2004

Heart failure and the risk of shocks in patients with implantable cardioverter defibrillators: results from the Triggers Of Ventricular Arrhythmias (TOVA) study.

Whang William, Mittleman Murray A, Rich David Q, Wang Paul J, Ruskin Jeremy N, Tofler Geoffrey H, Muller James E, Albert Christine M, TOVA Investigators

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Left ventricular ejection fraction (LVEF) predicts device discharges in patients with implantable cardioverter-defibrillators (ICDs). The relationship between severity of congestive heart failure (CHF) and ICD discharges is less clear.

METHODS AND

RESULTS

We prospectively analyzed the association between CHF and risk of appropriate ICD discharges in the Triggers Of Ventricular Arrhythmias (TOVA) study, a cohort study of ICD patients conducted at 31 centers in the United States. Reported shocks were confirmed for sustained ventricular tachycardia (VT) or fibrillation (VF) by analysis of stored electrograms. Proportional hazards models included CHF categorized by New York Heart Association class. Baseline CHF was present among 502 (44%) of 1140 patients; 170 (34%) had class I, 230 (46%) had class II, 97 (19%) had class III, and only 5 (1%) had class IV symptoms. During median follow-up of 212 days, 92 patients experienced 1 or more appropriate ICD discharges. Class III CHF was associated in a statistically significantly manner with ICD discharge for VT/VF (hazard ratio 2.40, 95% CI 1.16 to 4.98), even with adjustment for LVEF. The combination of LVEF <0.20 and class III symptoms resulted in a particularly high risk of shocks for VT/VF (hazard ratio 3.90, 95% CI 1.28 to 11.92).

CONCLUSIONS

Class III CHF, an easily accessible clinical measure, is an independent risk factor, along with LVEF, for ventricular arrhythmias that require shock therapy among ICD patients. Whether patients with class III CHF benefit to a greater degree from ICDs and whether aggressive treatment of CHF in ICD patients may prevent ventricular arrhythmias remains to be determined.

Для цитирования: Whang William, Mittleman Murray A, Rich David Q, Wang Paul J, Ruskin Jeremy N, Tofler Geoffrey H, Muller James E, Albert Christine M, TOVA Investigators. Heart failure and the risk of shocks in patients with implantable cardioverter defibrillators: results from the Triggers Of Ventricular Arrhythmias (TOVA) study.. Circulation. 2004. DOI: 10.1161/01.cir.0000120703.99433.1e.