MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circulationaha.113.007911

Медицинская библиотека · Circulation · 2014

Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures.

Milano Carmelo, Pagani Francis D, Slaughter Mark S, Pham Duc Thinh, Hathaway David R, Jacoski Mary V, Najarian Kevin B, Aaronson Keith D, ADVANCE Investigators

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Cardiac valve procedures are commonly performed concurrently during implantation of left ventricular assist devices, but the added procedural risk has not been studied in detail.

METHODS AND

RESULTS

Data from patients receiving the HeartWare Ventricular Assist Device in the ADVANCE bridge to transplant (BTT) trial and continued access protocol were reviewed. Of 382 consecutive patients who completed follow-up between August 2008 and June 2013 (mean time on support 389 days, median 271 days), 262 (68.6%) underwent isolated HeartWare Ventricular Assist Device implantation, 75 (19.6%) a concurrent valve procedure, and 45 (11.8%) concurrent nonvalvular procedures. Of the concurrent valve procedures, 56 were tricuspid, 13 aortic, and 6 mitral. Survival was similar between groups (79% for concurrent valve procedures and 85% for HeartWare Ventricular Assist Device only at 1 year; P=0.33). Concurrent valve procedures were also associated with increased unadjusted early right heart failure (RHF). A multivariable analysis for death and RHF (121 total events) identified female sex (odds ratio=2.0 [95% confidence interval, 1.2-3.3; P=0.0053]) and preimplant tricuspid regurgitation severity (odds ratio=2.9 [95% confidence interval, 1.8-4.8, P<0.0001]) as independent predictors while concurrent tricuspid valve procedures (TVP) were not predictors. Furthermore, patients with significant preimplant tricuspid regurgitation who did not receive a TVP experienced an increased rate of late RHF compared with those who received TVP (0.19 versus 0.05 events per patient-year, respectively; P=0.024).

CONCLUSIONS

Compared with HeartWare Ventricular Assist Device alone, survival was equivalent for the concurrent valve procedure group. Tricuspid regurgitation severity was the most important predictor of increased postoperative RHF, and concurrent TVP was not an independent predictor of RHF overall. Concurrent TVP may reduce the rate of late RHF for patients with significant preimplant tricuspid insufficiency.

CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00751972.

Для цитирования: Milano Carmelo, Pagani Francis D, Slaughter Mark S, Pham Duc Thinh, Hathaway David R, Jacoski Mary V, Najarian Kevin B, Aaronson Keith D, ADVANCE Investigators. Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures.. Circulation. 2014. DOI: 10.1161/circulationaha.113.007911.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.