Automatic quantitative measurement of left atrial pressure using mitral regurgitation spectrum: clinical study on comparison with floating catheter.

Jin Yan, Wen Chao-Yang, Yue Fengjie, Wang Huishan, Yin Liancheng, Zhao Yang, Mao Keming, Xin Fangran

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

To explore how to measure LAPEq accurately and quantitatively, that is, the left atrial pressure (LAP) measured and calculated by equation method using mitral regurgitation spectrum.

METHODS

The mitral regurgitation spectrum, pulmonary arteriolar wedge pressure (PAWP) and invasive arterial systolic pressure of radial artery of 28 patients were collected simultaneously, including 3 patients with rheumatic heart disease, 15 patients with mitral valve prolapse and 10 patients with coronary artery bypass grafting, patients with moderate or above aortic stenosis were excluded. LAPBp (Doppler sphygmomanometer method), LAPEq (Equation method) and LAPC (Catheter method) were measured synchronously, and the measurement results of the three methods were compared and analyzed. A special intelligent Doppler spectrum analysis software was self-designed to accurately measure LAPEq. This study had been approved by the ethics committee of the Northern Theater General Hospital (K-2019-17), and applied for clinical trial (No. Chictr 190023812).

RESULTS

It was found that there was no significant statistical difference between the measurement results of LAPC and LAPEq (t = 0.954, P = 0.348), and significant correlation between the two methods [r = 0.908(0.844, 0.964), P < 0.001]. Although the measurement results of LAPC and LAPBP are consistent in the condition of non-severe eccentric mitral regurgitation, there are significant differences in the overall case and weak correlation between the two methods [r = 0.210, (-0.101, 0.510), P = 0.090]. In MVP patients with P1 or P3 prolapse, the peak pressure difference of MR was underestimated due to the serious eccentricity of MR, which affected the accuracy of LAPBP measurement.

CONCLUSIONS

It was shown that there is a good correlation between LAPEq and LAPC, which verifies that the non-invasive and direct quantitative measurement of left atrial pressure based on mitral regurgitation spectrum is feasible and has a good application prospect.

Для цитирования: Jin Yan, Wen Chao-Yang, Yue Fengjie, Wang Huishan, Yin Liancheng, Zhao Yang, Mao Keming, Xin Fangran. Automatic quantitative measurement of left atrial pressure using mitral regurgitation spectrum: clinical study on comparison with floating catheter.. European journal of medical research. 2022. DOI: 10.1186/s40001-022-00849-y.