Towards a neurophysiological diagnostic marker of Alzheimer's disease using transcranial magnetic stimulation combined with electroencephalography.

Ben-Hayun Rachel, Zifman Noa, Hadad Rafi, Fogel Hilla, Levy-Lamdan Ofri, Verhovski Nastya, Yarovinsky Natalya, Ayoub-Agbaria Rawan, Tanne David

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BackgroundA scalable, objective measure of cortical function that differentiates Alzheimer's disease (AD) from other causes of cognitive impairment is still lacking. Transcranial magnetic stimulation combined with electroencephalography (TMS-EEG) enables direct assessment of cortical reactivity.ObjectiveTo test whether left primary motor cortex (M1L) P30 amplitude captures AD-related excitability changes, distinguishes biomarker-confirmed AD patients from controls (CN) and from other non-AD causes of cognitive impairment.MethodsNinety participants underwent M1L TMS-EEG with Delphi-MD: biomarker-confirmed AD (n = 22), other cognitively impaired (n = 27: vascular/mixed n = 12; frontotemporal dementia n = 4; unknown etiology n = 11), and CN (n = 41).ResultsP30 differed across biomarker-confirmed AD, other cognitively impaired, and CN (Quade F(2,80) = 4.989, p = 0.009, ηp2 = 0.11). Pairwise tests showed higher P30 in biomarker-confirmed AD versus other cognitively impaired (t = 2.117, p = 0.037, d = 0.61) and versus CN (t = 3.14, p = 0.002, d = 0.80). Among 27 clinically suspected AD tested for biomarkers, P30 was higher in biomarker + (22/27) versus biomarker- (5/27) (p = 0.035, d = 0.98), had good discriminatory performance for biomarker-confirmed AD (ROC = 0.853 [95% CIboot 0.627-1.000], p < 0.001), and was not associated with cerebrovascular changes (p = 0.455, d = 0.24).ConclusionsP30 amplitude is elevated in biomarker-confirmed AD relative to CN and other causes of cognitive impairment, aligning with amyloid-associated cortical hyperexcitability. These findings support P30 as a promising, non-invasive physiological biomarker to aid differential diagnosis and, potentially, disease monitoring in AD.Trial registry name and URL: https://clinicaltrial.health.gov.il/clinicaltrials/?MOHResearchId=MOH_2022-04-13_010726.

Для цитирования: Ben-Hayun Rachel, Zifman Noa, Hadad Rafi, Fogel Hilla, Levy-Lamdan Ofri, Verhovski Nastya, Yarovinsky Natalya, Ayoub-Agbaria Rawan, Tanne David. Towards a neurophysiological diagnostic marker of Alzheimer's disease using transcranial magnetic stimulation combined with electroencephalography.. Journal of Alzheimer's disease : JAD. 2026. DOI: 10.1177/13872877261463653.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.