The Effect and Safety of Dexmedetomidine Administration on Mother and Foetus/Neonates During General Anaesthesia in Caesarean Section: A Randomised Controlled Trial.

Yu Zhiqiang, Liu Yan, Duan Fangqi, Li Qian, Yan Dong, Zhang Li, Wang Zhuangzhuang, Zhang Minyu, Zhao Qi

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to assess the safety of dexmedetomidine administration to mothers, fetuses, and neonates during general anesthesia in cesarean section (CS).

PATIENTS AND

METHODS

A total of 60 parturients scheduled for elective CS under general anesthesia were randomly divided into anesthesia in groups (DEX1 and DEX2) and control (C) groups. Groups DEX1 and DEX2 were induced with dexmedetomidine (induction, 0.4 µg/kg; maintenance, 0.4 µg/kg·h) and dexmedetomidine (induction, 0.6 µg/kg; maintenance, 0.6 µg/kg·h), respectively, until birth. Equivalent volumes of normal saline were administered in group C. Anesthesia was induced with propofol and rocuronium in all groups. The mean arterial blood pressure (MAP) and heart rate (HR) of parturients were monitored and recorded; fetal HR was monitored using color doppler ultrasound. The blood gas analysis from the umbilical artery (UA) and umbilical vein (UV), along with the HR, Apgar score and Neurologic Adaptive Capacity Scores (NACS) of neonates, were recorded.

RESULTS

Maternal MAP at intubation/skin incision, maternal HR at intubation/skin incision and delivery were significantly lower in groups DEX1 and DEX2 than in group C, no significant differences were observed between groups DEX1 and DEX2. No significant differences were observed in fetal HR, UA and UV blood gas analyses, Apgar score and NACS of neonates in the three groups.

CONCLUSION

Intravenous 0.4 or 0.6 µg/kg doses of dexmedetomidine with propofol for general anesthesia in CS is beneficial for inhibiting the maternal stress response induced by intubation/skin incision and delivery without significant adverse effects on fetuses or neonates. Our findings suggest that dexmedetomidine is safe for mothers, fetuses, and neonates in obstetric general anesthesia.

Для цитирования: Yu Zhiqiang, Liu Yan, Duan Fangqi, Li Qian, Yan Dong, Zhang Li, Wang Zhuangzhuang, Zhang Minyu, Zhao Qi. The Effect and Safety of Dexmedetomidine Administration on Mother and Foetus/Neonates During General Anaesthesia in Caesarean Section: A Randomised Controlled Trial.. Journal of investigative surgery : the official journal of the Academy of Surgical Research. 2025. DOI: 10.1080/08941939.2025.2495089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.